The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
102
0
3

Year Published

2002
2002
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 165 publications
(108 citation statements)
references
References 2 publications
1
102
0
3
Order By: Relevance
“…In this study, the Actiheart was set up to record in IBI logging mode, storing activity every 15 s. Oxygen consumption (VO 2 ) and carbon dioxide (VCO 2 ) production rates were measured breath-by-breath with a portable indirect calorimetry system (K4b 2 , Cosmed s.r.l. Rome, Italy), previously validated (Hausswirth et al, 1997;McLaughlin et al, 2001). On all test days, gas analysers were calibrated against room air and a standard gas (16% O 2 , 5% CO 2 ) before the first test, at least 45 min after the equipment had been turned on.…”
Section: Prediction Of Pai During Walking and Runningmentioning
confidence: 99%
“…In this study, the Actiheart was set up to record in IBI logging mode, storing activity every 15 s. Oxygen consumption (VO 2 ) and carbon dioxide (VCO 2 ) production rates were measured breath-by-breath with a portable indirect calorimetry system (K4b 2 , Cosmed s.r.l. Rome, Italy), previously validated (Hausswirth et al, 1997;McLaughlin et al, 2001). On all test days, gas analysers were calibrated against room air and a standard gas (16% O 2 , 5% CO 2 ) before the first test, at least 45 min after the equipment had been turned on.…”
Section: Prediction Of Pai During Walking and Runningmentioning
confidence: 99%
“…El K4 system ha sido validado para medición del consumo de oxígeno y la frecuencia cardiaca en ejercicio 19 . Antes de cada ensayo se realizó la calibración del equipo para el análisis de O 2 y CO 2 , con mezcla de gases.…”
Section: Instrumentosunclassified
“…Additionally, others have suggested that the ideal experimental design when validating metabolic measurement systems would have simultaneous breath-by-breath data collection [11]. The CPX/D has been successfully used as a reference system during rest and varying intensities of exercise elsewhere [7,9,22,23]. …”
Section: Validity Of the Standard System For Comparisonmentioning
confidence: 99%
“…There are a number of automated metabolic measurement systems currently available on the market, each with specific strengths and limitations [7][8][9][10][11]. Typically however they require an integration of equipment, multiple test personnel and significant technical knowledge to run the systems and capture consistent and reliable data.…”
Section: Introductionmentioning
confidence: 99%