2012
DOI: 10.1007/s10967-012-2059-5
|View full text |Cite
|
Sign up to set email alerts
|

The design, construction, and initial characterization of an ultra-low-background gas-proportional counting system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(13 citation statements)
references
References 7 publications
0
13
0
Order By: Relevance
“…The isolated and concentrated sample could then be loaded (as a gas) into a low-background gas proportional counter for detection of the 32 P betas (using, e.g., the counters described in Ref. [75]). This approach has the advantage of involving limited handling and reagents, which should reduce the potential for introduction of the type of environmental radiocontaminants that will be a persistent challenge in the wet-chemistry methods described in Sec.…”
Section: Separation Of P-32 Via Gaseous Distillationmentioning
confidence: 99%
“…The isolated and concentrated sample could then be loaded (as a gas) into a low-background gas proportional counter for detection of the 32 P betas (using, e.g., the counters described in Ref. [75]). This approach has the advantage of involving limited handling and reagents, which should reduce the potential for introduction of the type of environmental radiocontaminants that will be a persistent challenge in the wet-chemistry methods described in Sec.…”
Section: Separation Of P-32 Via Gaseous Distillationmentioning
confidence: 99%
“…Ar was performed at PNNL using a low-background internal-source gas proportional counter. The detector utilizes high-purity electroformed copper and a niobium anode wire to reduce the background due to detector materials (Seifert et al, 2013). The design and construction of the detectors is detailed in Aalseth et al, 2009.…”
Section: Analysis Of 37mentioning
confidence: 99%
“…The design and construction of the detectors is detailed in Aalseth et al, 2009. The measurements of 37 Ar were made in PNNL's Shallow Underground Laboratory using the Ultra-Low-Background Counting System detailed in Aalseth et al, 2012 andSeifert et al, 2013.…”
Section: Analysis Of 37mentioning
confidence: 99%
“…After separation and purification, the argon fraction of the sample(s) was loaded into a gas proportional counter and taken to PNNL's shallow underground laboratory and counted [13].…”
Section: Ar Analysismentioning