2013
DOI: 10.3103/s1068371213010070
|View full text |Cite
|
Sign up to set email alerts
|

The development of multichamber arresters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…(i) a total of 86 equations, which were derived based on the law of mass action, of the following form: (1) where n i are the number densities of elements (atoms), n j is the number density of complex components (mol ecules), a i, j is the matrix of stoichiometric coefficients of reactions of decomposition of complex substances into atoms, K j (T, p) is the equilibrium constant of the corresponding reaction, and N = 7 is the number of chemical elements forming the system;…”
Section: Calculation Of the Composition Of Plasma Of An Arc Pulsed DImentioning
confidence: 99%
See 1 more Smart Citation
“…(i) a total of 86 equations, which were derived based on the law of mass action, of the following form: (1) where n i are the number densities of elements (atoms), n j is the number density of complex components (mol ecules), a i, j is the matrix of stoichiometric coefficients of reactions of decomposition of complex substances into atoms, K j (T, p) is the equilibrium constant of the corresponding reaction, and N = 7 is the number of chemical elements forming the system;…”
Section: Calculation Of the Composition Of Plasma Of An Arc Pulsed DImentioning
confidence: 99%
“…The use of multichamber arresters is now consid ered to be a new and promising way of protecting over head transmission lines from lightning overvoltages [1,2]. A multichamber arrester incorporates a great num ber of series connected chambers in which a pulsed arc discharge is initiated upon breakdown.…”
mentioning
confidence: 99%
“…The arc can be extinguished because of the nonlinear voltage and current characteristics of the MOV, but the cost of installing MOV arresters in a whole line is costly. Multi-chamber arc-extinguishing structures were first proposed by Podporkin [6,7]. They have attracted wide attention because of their excellent arc-extinguishing performance, relatively simple processing technology and low cost.…”
Section: Introductionmentioning
confidence: 99%
“…Multi-chamber arc-extinguishing structures with different numbers of SSACs can be applied to different voltage levels and different arc-extinguishing capacities [6][7][8]. There are three main reasons for the excellent arc-extinguishing capability of multi-chamber arc-extinguishing structures that can be summarized as follows: (1) The short arc energy in each SSAC maintains its combustion, and the air heated by the arc in the chamber produces a high-speed airflow, which increases the convective heat dissipation of the arc [9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation