2000
DOI: 10.1080/01425910008914356
|View full text |Cite
|
Sign up to set email alerts
|

The Early Design Model for Prediction of Energy and Cost Performance of Building Design Options

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Yohanis and Norton calculated the life-cycle energy (operational and embodied) of a UK generic single-storey office building, using Early Design Model EDM [68], which is an integrated simplified energy model based on a proven well-established algorithm, and studied the energy effects on the capital costs. They found that, there is a critical ratio of glazing which affects the balance between embodied and operational energy: embodied energy is higher below about 55%, but operational energy is higher above 55% glazing.…”
Section: Lca For Officesmentioning
confidence: 99%
“…Yohanis and Norton calculated the life-cycle energy (operational and embodied) of a UK generic single-storey office building, using Early Design Model EDM [68], which is an integrated simplified energy model based on a proven well-established algorithm, and studied the energy effects on the capital costs. They found that, there is a critical ratio of glazing which affects the balance between embodied and operational energy: embodied energy is higher below about 55%, but operational energy is higher above 55% glazing.…”
Section: Lca For Officesmentioning
confidence: 99%
“…EDM (Fig. 1) is an integrated and simplified energy model based on proven well-established algorithms and, being spreadsheet-based, is simple and flexible [36]. Included in the EDM are a generalized correlation for solar energy utilization [37] and a facility for preliminary cost evaluation [38].…”
Section: Energy Modelling Using Edmmentioning
confidence: 99%
“…It is assumed that the temperature in a room remains constant for the duration of the simulation. For a particular building description data set, good agreement has been obtained [36] between the annual heating energy predictions of EDM and that of SERI-RES; the latter is a detailed hour-by-hour simulation model [39,40]. During the heating season, the differences in prediction of heating energy varies from þ2.86 to 26.48 per cent with EDM over-estimating [36].…”
Section: Energy Modelling Using Edmmentioning
confidence: 99%
See 2 more Smart Citations