The Effect of Cation Distribution on Magnetic and Infrared Emission Properties of RE3+, MnO2:CoZn (RE = La,Ce,Pr,Nd,Sm,Eu,Gd,Tb, and Dy) Ferrite Ceramics

Abstract: The RE3+, MnO2:CoZn (RE = La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, and Dy) ferrite ceramics were prepared by solid‐state reaction method. The change in the magnetic and infrared emission properties of the samples due to the co‐doping of RE3+ and Mn4+ ions have been studied. X‐ray diffraction studies show that the main phase of the system is the spinel phase and the secondary phase (REFeO3) is formed on co‐doping of RE3+ and Mn4+ ions. The distribution of cation in the tetrahedral and octahedral sites was analyzed using… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 26 publications
(45 reference statements)
0
2
0
Order By: Relevance
“…Spectral absorptivity of the samples, uniaxially pressed into pellets at 300 MPa, was measured by ultraviolet–visible–near IR spectrophotometer (Cary5000; Varian, Sunnyvale, CA) equipped with an internal integrating sphere. IR emissivity of the pellet samples was measured by dual‐band IR emissometer (IR‐2; Shanghai Institute of Technological Physics, Shanghai, China), using a reflection method . Arithmetic average roughness ( R a ) of the pellet samples was measured by surface roughness tester (TR‐100; Beijing Time Group, Beijing, China).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Spectral absorptivity of the samples, uniaxially pressed into pellets at 300 MPa, was measured by ultraviolet–visible–near IR spectrophotometer (Cary5000; Varian, Sunnyvale, CA) equipped with an internal integrating sphere. IR emissivity of the pellet samples was measured by dual‐band IR emissometer (IR‐2; Shanghai Institute of Technological Physics, Shanghai, China), using a reflection method . Arithmetic average roughness ( R a ) of the pellet samples was measured by surface roughness tester (TR‐100; Beijing Time Group, Beijing, China).…”
Section: Methodsmentioning
confidence: 99%
“…IR emissivity of the pellet samples was measured by dual-band IR emissometer (IR-2; Shanghai Institute of Technological Physics, Shanghai, China), using a reflection method. 13 Arithmetic average roughness (R a ) of the pellet samples was measured by surface roughness tester (TR-100; Beijing Time Group, Beijing, China).…”
Section: Methodsmentioning