The effect of grounding system modeling on lightning-related studies of transmission lines

Abstract: Un-accurate modeling of power system may cause to under or over-design the insulation, which in turn, leads to increase in the investment and/or maintenance cost of the network protection against lightning overvoltages. The grounding system is an effective parameter on the magnitude of the lightning overvoltages and insulation coordination of high voltage transmission lines (TLs). This paper presents a comprehensive evaluation of the effect of grounding electrode impedance on the estimation of overvoltages cau… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 21 publications
1
11
0
2
Order By: Relevance
“…Sambaran petir bisa berbentuk sambaran langsung serta sambaran tidak langsung (Asna et al, 2022;Nugroho & Nugroho, 2022). Sambaran langsung ialah sambaran yang menuju ke konduktor fasa serta tiang (Shariatinasab & Gholinezhad, 2017). Sambaran tidak langsung merupakan kejadian sambaran yang berlangsung di sekitar sistem tenaga (Hajar & Rahman, 2018).…”
Section: Pendahuluanunclassified
“…Sambaran petir bisa berbentuk sambaran langsung serta sambaran tidak langsung (Asna et al, 2022;Nugroho & Nugroho, 2022). Sambaran langsung ialah sambaran yang menuju ke konduktor fasa serta tiang (Shariatinasab & Gholinezhad, 2017). Sambaran tidak langsung merupakan kejadian sambaran yang berlangsung di sekitar sistem tenaga (Hajar & Rahman, 2018).…”
Section: Pendahuluanunclassified
“…In case of Nano-Tch ground system design, the ground resistance reached micro or nano ohm resistance that is investigated the stability and reliability of the electric power stations. A more practical action may be to replace only that part of the soil that exercises the greatest influence on the ultimate grounding resistance and to use the lowest resistivity "soil" available [23][24][25].…”
Section: Trend Of Nanoparticles In Soil Earthig Systemsmentioning
confidence: 99%
“…Thus, a design of the grounding system needs to be planned, evaluated, and managed to achieve this vital objective [17]- [20]. Current grounding grid designs which are well described in standards and guidelines are based on homogenous soil conditions [15], [21]- [23].…”
Section: Introductionmentioning
confidence: 99%