1999
DOI: 10.1053/jvet.1999.0260
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Knotting Method on the Structural Properties of Large Diameter Nonabsorbable Monofilament Sutures

Abstract: Knotting method does influence the structural properties of suture materials and should be considered when tying knots under tension.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
64
2
7

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(74 citation statements)
references
References 28 publications
1
64
2
7
Order By: Relevance
“…Alternatively, the suture is knotted around a tube or rod that remains in the loop during the test (Rosin & Robinson, 1989). The clinical relevance of the ear technique has been questioned as the loop can pull through and the load is applied to the physician's side and not the patient's side of the knot (Huber et al, 1999;Thacker et al, 1975).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Alternatively, the suture is knotted around a tube or rod that remains in the loop during the test (Rosin & Robinson, 1989). The clinical relevance of the ear technique has been questioned as the loop can pull through and the load is applied to the physician's side and not the patient's side of the knot (Huber et al, 1999;Thacker et al, 1975).…”
Section: Introductionmentioning
confidence: 99%
“…The loop thus formed is removed and positioned around two right-angled rods that are placed in the jaws of a tensile tester (Annunziata et al, 1997;Bayraktar & Hockenberger 2001;Herrmann, 1971;Holmlund, 1974;Huber et al, 1999;Mishra, Cannon, Lucas, & Belzer, 1997;Nilsson, 1982;van Rijssel et al, 1989). While the load is applied to the patient's side, failure of the suture is usually by knot slippage, rather than knot failure.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of a needle holder to hold the first throw of the knot was intended to increase initial loop tension and stiffness, without compromising suture tensile strength (CAPORN;ROE, 1996;HUBER et al, 1999).…”
Section: Resultsmentioning
confidence: 99%
“…capitis femoris'in görevini yapacak yapay bir bağ oluşturulurken, bu amaçla farklı dikiş materyalleri kullanılmaktadır. En çok kullanılan dikiş materyalleri multiflament poliester, monofilament polipropilen ve monofilament poliamid'dir (cerrahi naylon dikiş materyali) (2,7,10,12). Dikiş materyalleri ile ilgili en önemli komplikasyon, bunların özellikle erken dönemde kopmaları sonucu şekillenen reluksasyonlardır (%18,5 -%25) ve genellikle operasyondan sonra 2. ve 8. haftalar arasında oluştuğu bildirilmiştir (3,5,10).…”
Section: Tartışma Ve Sonuçunclassified