The effect of laser profile, fluence, and spot size on sensitivity in orthogonal‐injection matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry

Abstract: The influence of incident laser parameters on sensitivity in matrix-assisted laser desorption/ionization (MALDI) has been investigated using orthogonal-injection time-of-flight (TOF) instruments. A qualitative comparison was first made between the beam profiles obtained with a N(2) laser and a Nd:YAG laser using 2-m long optical fibers. The N(2) laser gives better sensitivity, consistent with a more uniform fluence distribution and therefore better coverage of the N(2) laser profile. Most of the difference dis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
58
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 58 publications
(63 citation statements)
references
References 29 publications
5
58
0
Order By: Relevance
“…The I versus F curves shown within Figure 4 all have the similar general trends to those observed from peptides within the literature [2,7,9] whereby the low fluence data do not feature any detected ions, then as the fluence is increased past threshold, a steep rise in detected ion intensity is observed. For the single ion data, the curves then plateau soon after this initial increase and may even decrease again as fluence increases, whereas the TIC curves typically continue to increase to the maximum fluence, though the rate of increase is seen to drop off at the higher fluences, particularly for the 50 μm round fiber data (SI Figure S5).…”
Section: Optic Fiber Core Shape and Laser Beam Profilingsupporting
confidence: 76%
See 3 more Smart Citations
“…The I versus F curves shown within Figure 4 all have the similar general trends to those observed from peptides within the literature [2,7,9] whereby the low fluence data do not feature any detected ions, then as the fluence is increased past threshold, a steep rise in detected ion intensity is observed. For the single ion data, the curves then plateau soon after this initial increase and may even decrease again as fluence increases, whereas the TIC curves typically continue to increase to the maximum fluence, though the rate of increase is seen to drop off at the higher fluences, particularly for the 50 μm round fiber data (SI Figure S5).…”
Section: Optic Fiber Core Shape and Laser Beam Profilingsupporting
confidence: 76%
“…A threshold fluence of ion detection is typically reported as being between~20 and 1700 J/m 2 . The threshold energy and the effect of fluence on the detected ion intensity are also observed to depend upon the size of the irradiated area [1][2][3]. Beyond threshold energy, the rapid conversion of photons into heat leads to the creation of sub-surface nucleation, pressure waves, and subsequent molecule cluster and particle ejection [4,5].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In experiments where the focal laser spot was reduced to a diameter of 100 μm by utilizing a second optical fiber with smaller core diameter, no noticeable loss of sensitivity was observed (data not shown). We assume that a spatial resolution in the low 10 μm range could be achieved if further modifications were made (e.g., by employing fibers with core diameters in the 10 μm-range [16]). This could allow spatiallyresolved probing of fine features of the insect body like glands.…”
Section: Spatial Resolutionmentioning
confidence: 99%