2022
DOI: 10.1587/transcom.2021cep0014
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Multi-Directional on Remote Heart Rate Measurement Using PA-LI Joint ICEEMDAN Method with mm-Wave FMCW Radar

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
20
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 8 publications
(20 citation statements)
references
References 29 publications
0
20
0
Order By: Relevance
“…The phase-change information is then extracted from the most appropriate range bin cells along the time dimension, and it is unwrapped to calculate π‘₯(𝑑) . By the way, in order to increase the time utilization per frame and improve the phase quality, we propose the PA-LI method of emitting multiple up-chirp signals in each frame [29]. Finally, the vital signs are typically extracted from the π‘₯(𝑑) using a band-pass filter, wavelet transform, or other means.…”
Section: A Overview Of Measurement Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The phase-change information is then extracted from the most appropriate range bin cells along the time dimension, and it is unwrapped to calculate π‘₯(𝑑) . By the way, in order to increase the time utilization per frame and improve the phase quality, we propose the PA-LI method of emitting multiple up-chirp signals in each frame [29]. Finally, the vital signs are typically extracted from the π‘₯(𝑑) using a band-pass filter, wavelet transform, or other means.…”
Section: A Overview Of Measurement Methodsmentioning
confidence: 99%
“…However, EMD has issues with "mode mixing" and the "endpoint effect" [38], [39]. The ICEEMDAN method is an improved method based on EMD that can solve problems of the EMD and has been used to extract vital signs in our previous work [29], [40].…”
Section: Vital Signs Extraction Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, studies on heart rate measurement based on millimeter-wave FMCW radar have increased recently. For example, [3] describes the measurement of heart rate based on phase analysis of radar signals; in our previous work [4], we proposed a phase accumulation-linear interpolation (PA-LI) method to improve the signal-to-noise ratio (SNR) of the thoracic signal to obtain an accurate heartbeat signal, and evaluated it from multiple directions.…”
Section: Introductionmentioning
confidence: 99%