2023
DOI: 10.1002/cre2.726
|View full text |Cite
|
Sign up to set email alerts
|

The effect of preparation design on the fracture resistance and adaptation of the CEREC ceramic endocrowns

Abstract: Objective: The purpose of this experimental in vitro study was to assess the effect of having one or two intact axial walls on the improvement of the fracture resistance, and marginal and internal adaptation of computer-aided design/computer-aided manufacturer fabricated ceramic endocrowns.Materials and Methods: Thirty-six endodontically treated mandibular molars were divided into three groups (n = 12). Group A, represented teeth that all of their axial walls were reduced till they all had 3 mm height. In grou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 57 publications
0
4
0
Order By: Relevance
“…Overall, and based on the outcomes of the in vitro studies included in this systematic review, the recorded values of the marginal fitting, gap, and marginal adaptation of both LDGC and zirconia endocrowns were within the clinically acceptable value of <120 μm [ 40 , 41 ]. Some in vitro studies documented equal or slightly higher marginal gap values, as documented by Jalali et al, with 160 μm for zirconia CAD/DAM [ 14 ], and by Shin et al, with 138 μm for LDGC CAD/CAM [ 23 ]. An equal value of marginal adaptation or slightly lower values were obvious in laboratory studies conducted by Sağlam et al for both LDGC and zirconia CAD/CAM [ 27 ], LDGC endocrowns constructed with CAD/CAM or heat-press systems [ 25 ], and LDGC manufactured by CAD/CAM [ 22 ].…”
Section: Discussionmentioning
confidence: 96%
See 3 more Smart Citations
“…Overall, and based on the outcomes of the in vitro studies included in this systematic review, the recorded values of the marginal fitting, gap, and marginal adaptation of both LDGC and zirconia endocrowns were within the clinically acceptable value of <120 μm [ 40 , 41 ]. Some in vitro studies documented equal or slightly higher marginal gap values, as documented by Jalali et al, with 160 μm for zirconia CAD/DAM [ 14 ], and by Shin et al, with 138 μm for LDGC CAD/CAM [ 23 ]. An equal value of marginal adaptation or slightly lower values were obvious in laboratory studies conducted by Sağlam et al for both LDGC and zirconia CAD/CAM [ 27 ], LDGC endocrowns constructed with CAD/CAM or heat-press systems [ 25 ], and LDGC manufactured by CAD/CAM [ 22 ].…”
Section: Discussionmentioning
confidence: 96%
“…Endocrowns can be fabricated by CAD/CAM or heat-press techniques using various ceramic systems, such as lithium silicates and zirconia-reinforced lithium silicates [ 14 , 48 , 49 ]. A variety of the products are used in dental practice and produce prostheses with better accuracy of marginal variation [ 13 , 19 , 21 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations