1998
DOI: 10.1016/s0749-8063(98)70078-7
|View full text |Cite
|
Sign up to set email alerts
|

The effect of radiofrequency energy on the ultrastructure of joint capsular collagen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
73
0
5

Year Published

2001
2001
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 166 publications
(81 citation statements)
references
References 25 publications
3
73
0
5
Order By: Relevance
“…This uncoiling of collagen fibers and transition from a crystalline state to a random coil is responsible for collagen shortening, and transmission electron microscopy of collagenous tissues treated with RF ablation show collagen fibrils that increase in average diameter with increasing RF power. 30 Additionally, aligned collagen fibers fuse together in the orthogonal directions after treatment with RF ablation, [29][30] leading to modest changes seen in the radial direction here (Fig. 9D).…”
Section: Thermally-related Collagen Contracturementioning
confidence: 82%
“…This uncoiling of collagen fibers and transition from a crystalline state to a random coil is responsible for collagen shortening, and transmission electron microscopy of collagenous tissues treated with RF ablation show collagen fibrils that increase in average diameter with increasing RF power. 30 Additionally, aligned collagen fibers fuse together in the orthogonal directions after treatment with RF ablation, [29][30] leading to modest changes seen in the radial direction here (Fig. 9D).…”
Section: Thermally-related Collagen Contracturementioning
confidence: 82%
“…With Coblation 1 (ArthroCare Corporation) technology, radiofrequency energy is used to excite the electrolytes in a conductive medium such as saline solution to create a precisely focused plasma whose energized particles have sufficient energy to break the molecular bond in tissue, causing tissue to dissolve at relatively low temperature (typically 40°C to 70°C). Numerous Coblation 1 -based devices are in fact designed to seal bleeding vessels [6,10,15]. In addition, the radiofrequency wand has the capability of cutting in all directions with low resistance and therefore allows fine manipulation in narrow spaces [8].…”
Section: Discussionmentioning
confidence: 99%
“…More recently, the use of non-ablative, radio-frequency (RF) energy has been used to treat laxity in the anterior cruciate ligament, joint capsular region in the human shoulder and the lower face and neck [4][5][6][7]. RF devices have been used in thermal delivery systems to provide the beneficial effects of heat while avoiding some of the downfalls of more standard lasers [8].…”
Section: Introductionmentioning
confidence: 99%