2012
DOI: 10.1016/j.jcrc.2011.10.012
|View full text |Cite
|
Sign up to set email alerts
|

The flow-time waveform predicts respiratory system resistance and compliance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(24 citation statements)
references
References 20 publications
0
24
0
Order By: Relevance
“…The results of this study, assessing 12 mechanically ventilated individuals, showed strong correlation between compliance and resistance measures in VCV and PCV modes (r 2 = 0.73 and r 2 = 0.51, respectively). In the same study (9), the mean values in the VCV mode were 36.93 ± 12.18 mL/cm H2O for compliance, and 12.50 ± 2.99 cmH2O/L/sec for resistance. However, the normal range is described with a wide range of variation, comprising 50 to 100 mL/cmH2O for compliance and between 2 and 5 cmH2O/L/sec for the respiratory system resistance (18).…”
Section: Resultsmentioning
confidence: 60%
See 2 more Smart Citations
“…The results of this study, assessing 12 mechanically ventilated individuals, showed strong correlation between compliance and resistance measures in VCV and PCV modes (r 2 = 0.73 and r 2 = 0.51, respectively). In the same study (9), the mean values in the VCV mode were 36.93 ± 12.18 mL/cm H2O for compliance, and 12.50 ± 2.99 cmH2O/L/sec for resistance. However, the normal range is described with a wide range of variation, comprising 50 to 100 mL/cmH2O for compliance and between 2 and 5 cmH2O/L/sec for the respiratory system resistance (18).…”
Section: Resultsmentioning
confidence: 60%
“…The authors believe that this measure provides data on lung function and can describe the mechanics the motion equation and conversion of the nonlinear down flow to linear flow (9). The results of this study, assessing 12 mechanically ventilated individuals, showed strong correlation between compliance and resistance measures in VCV and PCV modes (r 2 = 0.73 and r 2 = 0.51, respectively).…”
Section: Resultsmentioning
confidence: 63%
See 1 more Smart Citation
“…The importance of ventilator graphics is well described in the literature 1234. We can see various patterns in pressure-volume loop, which are the characteristic features of different airway conditions including obstructive, restrictive lung diseases, intra-operative kinking etc 1234.…”
Section: Discussionmentioning
confidence: 93%
“…In this regard, tracing the utility of ventilators is worth mentioning. The importance of ventilator graphics cannot be over emphasised, as they provide useful information about airway, ventilation, compliance, and lung mechanics 12345. Some bizarre forms of graphics are usually overlooked as artefacts, but sometimes these tracings may in fact predict some relevant information.…”
Section: Introductionmentioning
confidence: 99%