2010
DOI: 10.1136/qshc.2009.032839
|View full text |Cite
|
Sign up to set email alerts
|

The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit

Abstract: ObjectiveAssess the impact of infusion pump technologies (traditional pump vs smart pump vs smart pump with barcode) on nurses' ability to safely administer intravenous medications.DesignExperimental study with a repeated measures design.SettingHigh-fidelity simulated inpatient unit.ResultsThe nurses remedied 60% of “wrong drug” errors. This rate did not vary as a function of pump type. The nurses remedied “wrong patient” errors more often when using the barcode pump (88%) than when using the traditional pump … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
94
0
5

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(105 citation statements)
references
References 22 publications
6
94
0
5
Order By: Relevance
“…Dentre os tipos de erros na AM encontrados nesta revisão, o principal deles diz respeito à dosagem medicamentosa, presente em 27 estudos (67,5%) (8,(10)(11)(13)(14)(16)(17)(19)(20)(23)(24)(25)(26)(27)(28)(30)(31)(32)34,36,(42)(43)(44)(45)(46)(47)(48)(49) . Corroborando com tal achado, uma pesquisa (50) que teve como um dos objetivos identificar o perfil dos erros cometidos durante o preparo, encontrou que 67,7% dos erros estavam associados a doses preparadas erroneamente.…”
Section: Discussionunclassified
See 1 more Smart Citation
“…Dentre os tipos de erros na AM encontrados nesta revisão, o principal deles diz respeito à dosagem medicamentosa, presente em 27 estudos (67,5%) (8,(10)(11)(13)(14)(16)(17)(19)(20)(23)(24)(25)(26)(27)(28)(30)(31)(32)34,36,(42)(43)(44)(45)(46)(47)(48)(49) . Corroborando com tal achado, uma pesquisa (50) que teve como um dos objetivos identificar o perfil dos erros cometidos durante o preparo, encontrou que 67,7% dos erros estavam associados a doses preparadas erroneamente.…”
Section: Discussionunclassified
“…Esta realidade também foi encontrada na presente pesquisa, em que a administração da medicação errada foi o segundo erro mais comum entre os estudos analisados e esteve presente em 62,5% (n=25) (8)(9)(10)(11)13,16,(20)(21)(23)(24)(25)(26)(28)(29)(30)(31)(36)(37)(42)(43)(45)(46)(48)(49)53) da amostra, seguido pelo medicamento administrado ao paciente errado (n=21;52,5%) (8)(9)(10)(11)16,18,22,(23)(24)(25)(26)(27)(28)(30)(31)(33)(34)(36)(37)(46)(47) .…”
Section: Discussionunclassified
“…Studies have mentioned that while these drug libraries do help catch many potential problems, there are still sources of errors that have not been fully addressed [23]. These included clinicians overriding soft and hard limits [21] and facilities setting soft warning levels too strictly or incorrectly.…”
Section: Case Studymentioning
confidence: 99%
“…There have been extensive studies by human factors experts and psychologists on the cognitive factors underlying human error [22,23,36]. Furthermore, the specific types of mistakes that operators commit while operating an infusion pump have also been well-studied and documented [3,9,20,24,28,37,40,47]. Table 2 lists some of the common pump programming errors as reported in the literature.…”
Section: Modeling Operator Mistakesmentioning
confidence: 99%
“…Mechanical failures are modeled using failure mode variables and transitions. Our approach incorporates models of pump programming errors based on generic human error models commonly studied in the human factors community [22,27,36] along with the results of studies and reports on the common types of errors committed by caregivers while programming infusion pumps [3,4,28,37,47]. The composition of these models yields an affine hybrid automaton.…”
Section: Introductionmentioning
confidence: 99%