The Indiana University midwest Proton Radiation Institute

Abstract: Funding to convert the IUCF K220 separated sector cyclotrons into a dedicated proton source for Cancer Therapy was released by Indiana University in August of 2000. Phase I of the Midwest Proton Radiation Institute (MPRI) will initially consist of the IUCF separated sector cyclotrons upgraded to operate at a fixed energy of 205 MeV, a treatment room containing both a general purpose large field horizontal fixed line and a small field line for the treatment of eye melanoma, a second treatment room with a 360 o … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
8
0

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 3 publications
0
8
0
Order By: Relevance
“…Installing a variable thickness energy degrader provides a fast, reliable and reproducible way of setting the beam energy, which is especially important for medical applications. Several proton radiation treatment centers including MPRI [1] and NPTC [2] plan on using variable energy degraders to set the beam energy for radiation treatments. A typical setup includes a variable thickness degrader followed by a momentum selection beam line that transfers the beam to a treatment room.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Installing a variable thickness energy degrader provides a fast, reliable and reproducible way of setting the beam energy, which is especially important for medical applications. Several proton radiation treatment centers including MPRI [1] and NPTC [2] plan on using variable energy degraders to set the beam energy for radiation treatments. A typical setup includes a variable thickness degrader followed by a momentum selection beam line that transfers the beam to a treatment room.…”
Section: Introductionmentioning
confidence: 99%
“…
This paper describes the optimization of a variable energy degrader design for the Midwest Proton Radiotherapy Institute (MPRI) [1]. To optimize the energy degrader design we investigate the choice of an optimal material for the degrader, the beam emittance growth in the degrader, and the matching of the degraded beam with the acceptance of a medical beam line.
…”
mentioning
confidence: 99%
“…One of the three aspects that they list to “democratize” protons is to reduce the costs of proton systems by doing away with expensive gantry systems and adopt fixed beam treatment rooms attaining multiple beam angles by rotating the patient in the beam. Fixed horizontal beams have been exploited in early systems to treat the patients in a seated position ( 88 , 89 ) and at Fermi Lab, patients were treated in an upright position with neutrons ( 90 , 91 ). Seated and upright treatments were until recently regarded as suboptimal arrangements forced on proton therapy when it was only available at physics research institutions, i.e., before the very large, expensive gantry systems were developed for and installed at hospital based and free-standing proton therapy clinics.…”
Section: Mechanics: the Advantages And Limits Of Arcs And Gantry-lessmentioning
confidence: 99%
“…The unique design requirements presented by MPRI [1] for patient positioning has yielded the design of a general system called The Patient Handling System or PHS (see figure 1). This system is responsible for locating a patient in the proton beam isocenter with the correct orientation, as prescribed by the treatment planning process.…”
Section: Introductionmentioning
confidence: 99%
“…
The Indiana University Cyclotron Facility (IUCF) is in the process of designing and building the Midwest Proton Radiation Institute (MPRI) [1]. The design process includes the development of several patient treatment systems.
…”
mentioning