2020
DOI: 10.3390/molecules25215018
|View full text |Cite
|
Sign up to set email alerts
|

The Influence of pH Values on the Rheological, Textural and Release Properties of Carbomer Polacril® 40P-Based Dental Gel Formulation with Plant-Derived and Synthetic Active Components

Abstract: The physicochemical properties, especially pH value of dental medicines, have significant influence on the health of oral cavity tissues. The pH of formulations should correspond to the value of saliva pH (5.5–8.0). For carbomer-based gels, the required pH value is obtained by neutralizing them with alkaline components, which leads to their structuring (thickening). This affects the physical properties of the gel, its residence time at the application site and the rate of release of active pharmaceutical ingre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
15
0
2

Year Published

2021
2021
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(28 citation statements)
references
References 33 publications
4
15
0
2
Order By: Relevance
“…Further, increasing pH is known to increase the viscosity of Carbopol gel. (47) The spreadability of all three hand sanitizer gel formulations increased with time. This is due to the drop in the viscosity of the tested formulations during storage.…”
Section: Discussionmentioning
confidence: 94%
“…Further, increasing pH is known to increase the viscosity of Carbopol gel. (47) The spreadability of all three hand sanitizer gel formulations increased with time. This is due to the drop in the viscosity of the tested formulations during storage.…”
Section: Discussionmentioning
confidence: 94%
“…Spreadability is an important characteristic to assess the spreading capabilities of the gel under the influence of facial muscle forces. The dosage form that is placed in between the buccal mucosa and the gingiva is pressed when the patient normally responds with facial expressions, speaking as well as ingesting reflexes [ 24 ]. Theoretically, there should be a definite value of spreadability so that the mucoadhesive surface area is exposed to mucosal tissue and the gel is not ingested during the former exercises of patient responses.…”
Section: Resultsmentioning
confidence: 99%
“…An Erweka SSP tester (ERWEKA GmbH, Germany) was used as device. The determination was performed according to the method 2.2.15 "Melting point -open tube capillary method" SPhU [22]. The sample considered to have passed the test if the melting point was ≤ 37.2 ° C.…”
Section: Research Of Technological Parameters Of Suppository Samplesmentioning
confidence: 99%