2008
DOI: 10.1007/978-1-59745-129-1_2
|View full text |Cite
|
Sign up to set email alerts
|

The Measurement of Nitric Oxide and Its Metabolites in Biological Samples by Ozone-Based Chemiluminescence

Abstract: A plethora of publications on techniques and methodologies for measuring nitric oxide (NO) or reaction products of NO (NO metabolites) has served in recent years to complicate and confuse the majority of researchers interested in this field. Here, we provide a practical approach and summarize the key issues and corresponding solutions regarding quantification with the use of ozone-based chemiluminescence, which is the most accurate, sensitive, and widely used NO detection method. We have drawn on the vast expe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
58
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 51 publications
(59 citation statements)
references
References 6 publications
1
58
0
Order By: Relevance
“…Certainly in our hands [13] there remains noticeable variation in both time to peak, and peak plasma [ . It is tempting to speculate this reflects mainly differences in dealing with and/or storing the plasma sample as we and others have demonstrated [15]. There is no observable trend to indicate higher baseline plasma levels influence the peak yield, but this remains to be tested directly.…”
Section: Individual Versus Group Variationmentioning
confidence: 80%
“…Certainly in our hands [13] there remains noticeable variation in both time to peak, and peak plasma [ . It is tempting to speculate this reflects mainly differences in dealing with and/or storing the plasma sample as we and others have demonstrated [15]. There is no observable trend to indicate higher baseline plasma levels influence the peak yield, but this remains to be tested directly.…”
Section: Individual Versus Group Variationmentioning
confidence: 80%
“…Additionally, at least one solvent filter should be placed in-line between the condenser and the NOA (Whatman, solvent IFD). The condenser(s) and filter(s) ensure that the gas stream from the purge vessel to the NOA is as dry as possible [10], eliminating any possible quenching of NO • signal by water vapor [17], while also protecting the NOA reaction cell from moisture and possible damage [18]. The condenser also optimizes the NO • + O 3 reaction in the NOA, which is reduced at higher temperatures [19].…”
Section: 0 Materials and Methodsmentioning
confidence: 99%
“…It exploits the luminescent nature of the reaction between NO • and O 3 [18]. An O 2 source tank is used to generate O 3 in the NOA reaction cell [18].…”
Section: 0 Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations