This article deals with a static and quasi-static load using the maximum power of a hydraulic pump. Additionally, quasi-static coefficients for the partially embedded rock bolts were determined. The laboratory tests included 2.2 m long bolts, which were embedded segmentally on the lengths of 0.05 m, 0.3 m and 0.9 m and were tested. To fix the ribbed bolt rods in the steel cylinders, resin cartridges with a length of 0.45 m long were used. The main aim of the research was to determine the load-displacement characteristics. Knowing the bolt rod tensile mechanism, the points of failure in the material continuity were identified, on the basis of which stress-strain characteristics are made. Particular attention was paid to the definition of: tensile stress for the yield point (σ1), maximum stress (σ2), stress at failure (σ3), strain in the elastic range (ε1), strain for maximum stress (ε2) and strain corresponding to the failure (ε3).