2014
DOI: 10.1155/2014/541726
|View full text |Cite
|
Sign up to set email alerts
|

The Numerical Investigation of Temperature and Velocity Distribution in the High-Bay Depot

Abstract: High-bay depot plays an important role in the storage industry. Due to large and high space of high-bay depot, it is difficult to make temperature distribution uniform, which will influence the storage time of raw materials. In this paper, the aim is to find the reasonable air supply and energy-saving method; a supply-air method of high-bay depot is investigated as an example. The results show the radius and spacing of the supply-air inlet have great influence on temperature distribution. The temperature nonun… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…9 Liu and Novoselac 10 measured the ADPI values of three widely used adjustable diffusers: adjustable-blade grills, fixed-blade grills and ceiling linear slot diffusers, at various deflector configurations in a test room. Wu et al 11 adopted the temperature non-uniformity coefficients of summer and winter to investigate a reasonable air supply and energy-saving method of high-bay depot based on CFD. Fan 12 analysed the impact of air supply control strategies (louvers movement) on indoor thermal environment and evaluated the temperature uniformity using the ADPI to determine the air diffusion performance of a room in heating mode.…”
Section: Introductionmentioning
confidence: 99%
“…9 Liu and Novoselac 10 measured the ADPI values of three widely used adjustable diffusers: adjustable-blade grills, fixed-blade grills and ceiling linear slot diffusers, at various deflector configurations in a test room. Wu et al 11 adopted the temperature non-uniformity coefficients of summer and winter to investigate a reasonable air supply and energy-saving method of high-bay depot based on CFD. Fan 12 analysed the impact of air supply control strategies (louvers movement) on indoor thermal environment and evaluated the temperature uniformity using the ADPI to determine the air diffusion performance of a room in heating mode.…”
Section: Introductionmentioning
confidence: 99%
“…The obtained results are useful as a theoretical background for the highbay depot design and economical operation. [4].…”
Section: Introductionmentioning
confidence: 99%