2002
DOI: 10.1556/jpc.15.2002.5.1
|View full text |Cite
|
Sign up to set email alerts
|

The performance of planar electrochromatography in a horizontal chamber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
5
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(6 citation statements)
references
References 5 publications
1
5
0
Order By: Relevance
“…A higher buffer concentration leads to an increase in the mobile phase flow rate (slope of the relationship). This effect is consistent with previous data presented for capillary electrochromatography, planar electrochromatography in opened systems, and planar electrochromatography in closed systems . However, interpretation of the effect is more complicated due to the influence of the buffer concentration on the ζ potential and double layer thickness, which can overlap in the particulate stationary phase of the electrochromatography system.…”
Section: Resultssupporting
confidence: 91%
See 3 more Smart Citations
“…A higher buffer concentration leads to an increase in the mobile phase flow rate (slope of the relationship). This effect is consistent with previous data presented for capillary electrochromatography, planar electrochromatography in opened systems, and planar electrochromatography in closed systems . However, interpretation of the effect is more complicated due to the influence of the buffer concentration on the ζ potential and double layer thickness, which can overlap in the particulate stationary phase of the electrochromatography system.…”
Section: Resultssupporting
confidence: 91%
“…The separation performance measured by theoretical plate height was several times higher in the PEC system in comparison to TLC, and the development time was several times shorter. The experiments were performed in a special device for PEC in which the chromatographic plate was almost vertically 9 and horizontally , mounted.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…Electroosmosis is used to drive the mobile phase flow through the layer in pressurized planar electrochromatography and requires an aqueous buffer as a component of the mobile phase [23,[57][58][59][60][61][62]]. An electric field applied across the layer is used to control the mobile phase velocity which is independent of the solvent front migration distance.…”
Section: Pressurized Planar Electrochromatographymentioning
confidence: 99%