“…As previously described, 27 the bone marrow samples were collected during the scheduled open reduction and internal fixation of the hip or long bone fracture for the trauma and hip replacement patients, using an 11-gauge bone marrow biopsy needle (Covidien, Minneapolis, MN) at the fracture site. An investigator (TJL, ESM, CGA, JAS) was present in the operating room for collection of all bone marrow samples, which were obtained from the sterile field by an orthopedic surgeon (JEH, HKP, KKS, MP) to ensure consistency of the sample collection.…”