1992
DOI: 10.1097/01823246-199203010-00013
|View full text |Cite
|
Sign up to set email alerts
|

The Quadrilateral Socket and CAT-CAM Socket: A Comparison of Metabolic Cost During Ambulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(21 citation statements)
references
References 0 publications
0
21
0
Order By: Relevance
“…In the slow walking phase, they observed higher VO2 (ptO.05) and HR (pt0.01) in the quadrilateral and CAD/CAM groups than in the control group. However, there was no significant difference between quadrilateral and CAD/CAM sockets groups with respect to VO2 or HR [25]. The present study evaluated the walking time with the prosthesis.…”
Section: Discussionmentioning
confidence: 71%
See 1 more Smart Citation
“…In the slow walking phase, they observed higher VO2 (ptO.05) and HR (pt0.01) in the quadrilateral and CAD/CAM groups than in the control group. However, there was no significant difference between quadrilateral and CAD/CAM sockets groups with respect to VO2 or HR [25]. The present study evaluated the walking time with the prosthesis.…”
Section: Discussionmentioning
confidence: 71%
“…Early and immediate prosthetic fitting decreases oedema and positively contributes to wound healing, residual limb shaping, development of proprioception, and patients' psychological condition [14]. It is considerably difficult to produce prostheses, perform adjustments, and record information using conventional methods [25]. Furthermore, casting involves additional difficulties for the leg [15].…”
Section: Discussionmentioning
confidence: 99%
“…It is also termed CAT CAM (Contoured Adducted Trochanteric Controlled Alignment Method) or ''ischial ramal weight bearing socket'', because it encloses the ischial tuberosity and the ramus within the socket. For more than two decades, the IC socket supplanted the quadrilateral socket, also because it reduces the energy cost of walking [2]. Then, about ten years ago Marlo Ortiz Vasquez developed the Marlo Anatomical Socket (MAS 1 ) for TF amputees (Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Several investigators have demonstrated that the increase in prosthetic weight results in increased metabolic cost [7]. The energy consumption of an amputee can be minimized up to 56% by using light weight socket with increased heat transfer rate [8]. The existing socket material is heavy and has poor heat transfer rate, which is a huge concern for the amputee.…”
Section: Introductionmentioning
confidence: 99%
“…Another layer of stockinette was placed on top of this and a required amount of polyester resin mixture was poured. The set of layers was repeated again till we get the desired number of sandwich-structured composite (2,4,6,8,10). Finally, the composite was cured for 4 hr in room temperature to get the sandwich-structured composite.…”
mentioning
confidence: 99%