1993
DOI: 10.1007/bf01627635
|View full text |Cite
|
Sign up to set email alerts
|

The Relaxometer: A complete and comprehensive computer-controlled neuromuscular transmission measurement system developed for clinical research on muscle relaxants

Abstract: The Relaxometer is a computer-controlled system developed for reliable clinical experimental measurements on neuromuscular block. This system is based on an adapted personal computer (Atari 1040 ST) with a monochrome monitor (Atari SM 124), and a microcomputer-driven slave unit (stimulator). There are several stimulation patterns available: single twitch at 0.1 and 1 Hz, single train-of-four, continuous train-of-four every 12 seconds, and tetanic stimulation at 50 Hz for 5 seconds followed by posttetanic count… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

1994
1994
2007
2007

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(20 citation statements)
references
References 23 publications
0
19
0
Order By: Relevance
“…Recordings of the single twitch contractions of the adductor pollicis muscle were obtained by stimulating the ulnar nerve at the wrist using surface electrodes with supramaximal squarewave stimuli of 0.2 msec duration at a frequency of 0.1 Hz. The resultant force of thumb adduction was quantified via a force displacement transducer after applying a resting tension of 200 -400 g and recorded via a Relaxometer 2 6 and calculated using a closed loop infusion computer program with an algorithm included. The closed-loop control system is based on a fuzzy logic system and consists of 32 fuzzy rules inferencing over three inputs (error, relaxation rate of change, relaxation stability).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recordings of the single twitch contractions of the adductor pollicis muscle were obtained by stimulating the ulnar nerve at the wrist using surface electrodes with supramaximal squarewave stimuli of 0.2 msec duration at a frequency of 0.1 Hz. The resultant force of thumb adduction was quantified via a force displacement transducer after applying a resting tension of 200 -400 g and recorded via a Relaxometer 2 6 and calculated using a closed loop infusion computer program with an algorithm included. The closed-loop control system is based on a fuzzy logic system and consists of 32 fuzzy rules inferencing over three inputs (error, relaxation rate of change, relaxation stability).…”
Section: Methodsmentioning
confidence: 99%
“…Skin temperature at the site of the surface electrodes was monitored and recorded continuously with the Relaxometer 2 6 and kept > 33.0°C.…”
Section: Methodsmentioning
confidence: 99%
“…The neuromuscular blocking effects were measured by mechanomyography using the Relaxometer (University of Groningen, The Netherlands) [5]. After induction of anaesthesia and calibration of the neuromuscular monitoring equipment, the ulnar nerve was stimulated at the wrist using surface electrodes.…”
Section: Neuromuscular Measurementsmentioning
confidence: 99%
“…The arm was wrapped to keep the temperature of the hand above 32.58C. Preload was kept constant at 200-400 g. The isometric contraction of the adductor pollicis muscle was measured by a force transducer and recorded online (Relaxometer, Groningen, the Netherlands) [12]. Monitoring continued until the ST response recovered to its pre-relaxation control value.…”
Section: Anesthesiamentioning
confidence: 99%