The resolution dependence of optimal exposures in liquid nitrogen temperature electron cryomicroscopy of catalase crystals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
66
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 76 publications
(73 citation statements)
references
References 39 publications
7
66
0
Order By: Relevance
“…Similarly, later frames collected during the exposure are expected to display greater radiation damage effects and can also be discarded to preserve high-resolution features, as shown in our analysis. Our finding that the use of just the first 10 e − /A 2 produces density maps with the least radiation damage is consistent with estimates of the optimal dose to obtain density maps at 3-Å resolution by using cryo-EM (42). In addition to reducing the effects of beaminduced motion and mitigating the effects of radiation damage, we show that dose fractionation can also be used to improve the accuracy of contrast transfer function (CTF) estimation, which is an important resolution-limiting factor in single-particle cryo-EM (ref.…”
Section: Significancesupporting
confidence: 82%
“…Similarly, later frames collected during the exposure are expected to display greater radiation damage effects and can also be discarded to preserve high-resolution features, as shown in our analysis. Our finding that the use of just the first 10 e − /A 2 produces density maps with the least radiation damage is consistent with estimates of the optimal dose to obtain density maps at 3-Å resolution by using cryo-EM (42). In addition to reducing the effects of beaminduced motion and mitigating the effects of radiation damage, we show that dose fractionation can also be used to improve the accuracy of contrast transfer function (CTF) estimation, which is an important resolution-limiting factor in single-particle cryo-EM (ref.…”
Section: Significancesupporting
confidence: 82%
“…In 2013, a new method for cryo-EM was unveiled and termed MicroED, or 3D electron crystallography of microscopic crystals (Shi et al, 2013;Nannenga et al, 2014b). With continuous rotation MicroED, which is the preferred method of data collection in MicroED, significant loss of diffraction intensity was observed at resolutions better than ~3 Å when only ~3 e -Å -2 were used, consistent with past studies (Hayward & Glaeser, 1979;Jeng & Chiu, 1984;Baker et al, 2010).…”
Section: Introductionsupporting
confidence: 54%
“…Past studies of radiation damage in cryo-EM described the exposure-dependent decay of diffraction intensities up to and including 3 Å resolution Hayward & Glaeser, 1979;Jeng & Chiu, 1984;Baker et al, 2010). No data was analyzed at resolutions better than 3 Å likely because such data was not recorded at the time.…”
Section: Discussionmentioning
confidence: 99%
“…Images were acquired under low-dose conditions at defoci between 3 and 7 μm. For untilted images, electron exposures of 25-30 e − /Å 2 were used to optimize signal-to-noise ratios for spatial frequencies corresponding to information between 20 and 50 Å (43). For pairs of tilted images, this exposure was divided evenly between the first image (with a goniometer setting of +15°) and the second image (with a goniometer setting of −15°).…”
Section: Methodsmentioning
confidence: 99%