2021
DOI: 10.1177/15910199211024061
|View full text |Cite
|
Sign up to set email alerts
|

The Silk Vista Baby – The UK experience

Abstract: Background The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. Materials and Methods We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. Results We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(23 citation statements)
references
References 55 publications
2
21
0
Order By: Relevance
“…30 Overall, complications and major events associated with the SVB are reported to be low, occurring in approximately 2.27% to 3.3% of cases. 14,16 Our results reinforce the safe profile of the device for the treatment of true PICA aneurysms. Of the 3 adverse events seen in our study, only 1 can be related directly to the procedure, where 1 patient developed transient hyposensitivity due to perforator occlusion.…”
Section: Discussionsupporting
confidence: 75%
See 3 more Smart Citations
“…30 Overall, complications and major events associated with the SVB are reported to be low, occurring in approximately 2.27% to 3.3% of cases. 14,16 Our results reinforce the safe profile of the device for the treatment of true PICA aneurysms. Of the 3 adverse events seen in our study, only 1 can be related directly to the procedure, where 1 patient developed transient hyposensitivity due to perforator occlusion.…”
Section: Discussionsupporting
confidence: 75%
“…Major complications ranged from 1.6% to 2.3%. 14-16,28 Moreover, there were no other complications related to the treatment, and 11 patients from 24 had complete occlusions at their 3-month follow-up.…”
Section: Discussionmentioning
confidence: 90%
See 2 more Smart Citations
“…Use of low-profile FDs in small arteries with a diameter of < 3 mm have increased recently [ 2 , 17 19 ]. FRED Jr’s distinctive design provides the advantage of side branch protection in complex aneurysms.…”
Section: Discussionmentioning
confidence: 99%