“…This baseline was subtracted from the spectra which were then exported to Peakfitv4.12 software in order to calculate the area under the bands of interest. 29 Si NMR analysis of selected samples was undertaken using 29 Si NMR analysis was undertaken using a Varian Unity Inova 300. 0.5-1.0 grams of powdered samples were tested at the EPSRC National Solid State NMR service at the University of Durham, UK.…”
Section: Structural Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…This baseline was subtracted from the spectra which were then exported to Peakfitv4.12 software in order to calculate the area under the bands of interest. 29 Si NMR analysis of selected samples was undertaken using 29 Si NMR analysis was undertaken using a Varian Unity Inova 300. 0.5-1.0 grams of powdered samples were tested at the EPSRC National Solid State NMR service at the University of Durham, UK.…”
Section: Structural Analysismentioning
confidence: 99%
“…0.5-1.0 grams of powdered samples were tested at the EPSRC National Solid State NMR service at the University of Durham, UK. The chemical shifts of the 29 Si NMR spectra of the samples are referenced to tetramethylsilane (TMS). Pulse angle, acquisition time and resonance frequency were set to 45°, 40.00 ms and 59.557 MHz respectively.…”
Section: Structural Analysismentioning
confidence: 99%
“…lithium). Inspection of a large body of chemical shift trends in various mixed-alkali glasses suggests that these structural readjustments are rather universal [59][60][61][62][63][64][65][66][67][68][69][70][71][72][73][74]: substitution of an alkali ion A by larger homologue B always leads to a slight compression of the A site and an expansion of the B site, compared to the situation in the corresponding single-alkali glass. Based on this evidence for site modification, we have suggested an additional ("secondary") mismatch effect as a fundamental principle underlying the MAE, which seems particularly relevant in the dilute foreign ion limit (see Fig.…”
Section: Site Modifications and Secondary Mismatch Effectsmentioning
confidence: 99%
“…The structure of the NS4 glass has been intensively investigated by different experimental methods [2], reverse Monte Carlo (RMC) [3] as well as classical molecular dynamics (MD) simulations [4,5]. Recently, the structural and electronic properties of the NS4 glass have been modeled by a combined Car-Parrinello and classical MD simulation [6,7].…”
Section: Introductionmentioning