2020
DOI: 10.1007/s12221-020-9741-y
|View full text |Cite
|
Sign up to set email alerts
|

The Superhydrophobic State Stability of Coatings Based on Copolymers of Glycidyl Methacrylate and Alkyl Methacrylates on Cotton Fabric Surface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 31 publications
1
7
0
Order By: Relevance
“…8 CNs-P@M-PG showed absorption bands at 1250, 908, and 840 cm À1 (epoxide ring deformation) and 1724 cm À1 (O] C-O tensile deformation), indicating the successful polymerization of PGMA. 52,55,56 At the same time, the new absorption bands of CNs-P@M-PG-NEO and CNs-P@M-PG-PHGH at 1633 cm À1 (C]N stretching vibration) and 1309 cm À1 (C-N stretching) conrmed the existence of NEO and PHGH. 41,52,57 According to the wide scan spectra of X-ray photoelectron spectroscopy (XPS) (Fig.…”
Section: Fabrication Of Functionalized Cns-p@m-pg-neo/phghmentioning
confidence: 90%
“…8 CNs-P@M-PG showed absorption bands at 1250, 908, and 840 cm À1 (epoxide ring deformation) and 1724 cm À1 (O] C-O tensile deformation), indicating the successful polymerization of PGMA. 52,55,56 At the same time, the new absorption bands of CNs-P@M-PG-NEO and CNs-P@M-PG-PHGH at 1633 cm À1 (C]N stretching vibration) and 1309 cm À1 (C-N stretching) conrmed the existence of NEO and PHGH. 41,52,57 According to the wide scan spectra of X-ray photoelectron spectroscopy (XPS) (Fig.…”
Section: Fabrication Of Functionalized Cns-p@m-pg-neo/phghmentioning
confidence: 90%
“…Attachment of GMA‐based copolymers to the wood surface was carried out according to the “grafting to” approach (Figure 2). The reaction between oxirane rings of copolymers and hydroxyl groups of wood (in particular cellulose) is possible at elevated temperatures (140°C) 39–41 . The attachment of copolymers on the surface of wood is confirmed by FTIR spectroscopy (Figures S1, S2 in supplemental materials).…”
Section: Resultsmentioning
confidence: 80%
“…The contact angle was measured using an OCA 15EC apparatus from DataPhysics (Filderstadt, Germany) according to the procedure described in [35]. The contact angle measurements were performed by applying 5 µL drops of test liquid on the surface of the material at room temperature in several environments, i.e., air, nonpolar liquid (diesel fuel), and polar liquid (deionized water).…”
Section: Methodsmentioning
confidence: 99%