2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings 2016
DOI: 10.1109/i2mtc.2016.7520459
|View full text |Cite
|
Sign up to set email alerts
|

The unbundled smart meter concept in a synchro-SCADA framework

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…Mihaela M et al in their papers [11] and [12] proposed power quality (PQ) monitoring and control using voltage parameter assessment feature implemented in USM. Mihai Sanduleac et al in their researches [13], [14], [15] addressed the LV network observability and control issues and proposes the solution of USM architecture. Mihai Sanduleac et al [16] also presented an approach in his research article for integrating Electrical Vehicles in the Smart Grid with the application of unbundled Smart Metering.…”
Section: Robust State Feedback Controller For Photovoltaic Inverter Smentioning
confidence: 99%
See 1 more Smart Citation
“…Mihaela M et al in their papers [11] and [12] proposed power quality (PQ) monitoring and control using voltage parameter assessment feature implemented in USM. Mihai Sanduleac et al in their researches [13], [14], [15] addressed the LV network observability and control issues and proposes the solution of USM architecture. Mihai Sanduleac et al [16] also presented an approach in his research article for integrating Electrical Vehicles in the Smart Grid with the application of unbundled Smart Metering.…”
Section: Robust State Feedback Controller For Photovoltaic Inverter Smentioning
confidence: 99%
“…shows a three-phase grid connected inverter, where Vpv denotes the DC-Link voltage R and L are the filter resistances and filter inductances, respectively.From figure 1, the system can be mathematically expressed in synchronous reference frame as: 8), (9),(10) and(11) the state space model of the inverter can be obtained as(12) (13) …”
mentioning
confidence: 99%
“…The Storage4Grid Operations Concept is depicted in Fig. 2 and focuses on the technical infrastructure required to control ESS in cooperative scenarios, building upon several innovative components developed in previous projects such as the Unbundled Smart Meter (USM) and the Energy Router (ER) developed by FlexMeter and Nobelgrid [4], [5], [6]. The USM is connected to the local communication network at user premises and interacts with the EV charging stations, storage, local users and other local systems.…”
Section: The Storage4grid Projectmentioning
confidence: 99%
“…-Network synchronization of SMX time with accuracy better than one second, to allow synchronous data acquisition over the entire Smart Grid metering points [3].…”
Section: Introductionmentioning
confidence: 99%