1997
DOI: 10.1177/039139889702000308
|View full text |Cite
|
Sign up to set email alerts
|

The Use of a Heparin Removal Device: A Valid Alternative to Protamine

Abstract: Purpose Experiments were carried out to test the efficacy and safety of the heparin removal device, a plasmapheresis filter that binds and eliminates heparin, in the context of extracorporeal circulation. Procedures and Findings Six dogs were put on cardiopulmonary bypass after heparinization. Upon weaning, additional heparin was administered to obtain an activated clotting time above 900s. The animals were connected to the heparin removal device and with flows of 500 ml/min, activated clotting time, activated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1999
1999
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…Animal experiments have demonstrated the efficiency of the device without any adverse effects. [8][9][10][11] No blood component damage was observed, there were no significant changes in haematocrit level, leucocyte profiles or platelets, 9 and haemodynamics remained stable. The optimal regimen is nevertheless not clearly defined.…”
Section: Discussionmentioning
confidence: 88%
“…Animal experiments have demonstrated the efficiency of the device without any adverse effects. [8][9][10][11] No blood component damage was observed, there were no significant changes in haematocrit level, leucocyte profiles or platelets, 9 and haemodynamics remained stable. The optimal regimen is nevertheless not clearly defined.…”
Section: Discussionmentioning
confidence: 88%
“…Although intravenous administration of protamine alone could produce systemic hypotension, myocardial depression, and an increase in vascular permeability ( , ), it has been demonstrated clinically that the combined use of protamine and heparin actually triggers the activation of complement system that subsequently elicits more toxic responses ( , ). The quest for a better protamine alternative is therefore in profound scrutiny in recent years ( ).…”
Section: Introductionmentioning
confidence: 99%
“…Other approaches to suppress complement activation use heparin-coated (34) or heparin removal devices (35). The disadvantage of these efforts is that these devices only inhibit activation on biomaterials and have no effect on complement activation caused by gas surfaces or reperfusion of previously ischemic tissues.…”