2018
DOI: 10.1021/acscatal.8b02120
|View full text |Cite
|
Sign up to set email alerts
|

The Use of Controls for Consistent and Accurate Measurements of Electrocatalytic Ammonia Synthesis from Dinitrogen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

4
303
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 279 publications
(307 citation statements)
references
References 24 publications
4
303
0
Order By: Relevance
“…Notably,i fa ll this extra increased reduction current is used for the NRR under the N 2 -saturated environment (Figure 3a), the NH 3 yield rate at À0.3 Vversus RHE is calculated to be 119.6 mg NH 3 h À1 mg cat. [40][41][42] Moreover, 1 HNMR spectroscopy with isotope-labeled 15 N 2 [43] confirms that the ammonia detected in the NRR experiments was produced from the NRR ( Figure S17). À1 ).…”
mentioning
confidence: 56%
“…Notably,i fa ll this extra increased reduction current is used for the NRR under the N 2 -saturated environment (Figure 3a), the NH 3 yield rate at À0.3 Vversus RHE is calculated to be 119.6 mg NH 3 h À1 mg cat. [40][41][42] Moreover, 1 HNMR spectroscopy with isotope-labeled 15 N 2 [43] confirms that the ammonia detected in the NRR experiments was produced from the NRR ( Figure S17). À1 ).…”
mentioning
confidence: 56%
“…Nevertheless, the commonly used spectroscopic assays could be impacted by changes in the solution conditions, thus requiring a secondary verification using N 15 ‐labeled N 2 . We should note that commercial N 15 ‐labeled N 2 may contain trace amount of 15 NH 4 + , 15 NO 2 − , and other impurities that need to be removed before being applied into the catalytic system . Treating the 15 N 2 gas with sulfuric acid overnight before the experiment has been reported in literature to remove impurities .…”
Section: Discussionmentioning
confidence: 99%
“…Accurate comparation of reported catalyst performance can only be achieved should there be reliable data available. Standard guidelines for control experiments should be followed to exclude any ammonia contamination . By conducting these rigorous control experiments, the possibility of false‐positive results should be minimized, enabling researchers to normalize the catalyst performance for the comparation of the intrinsic catalytic properties.…”
Section: Discussionmentioning
confidence: 99%
“…Qiao and co‐workers have suggested that at least two detection methods should be used for the detection of NH 3 and a third should there be obvious difference in the results . Recently, Greenlee et al have proposed a general protocol for consistent and accurate measurements of the ammonia production during electrocatalysis, as shown in Figure . It is suggested that 15 N isotope study should be carried out to verify the NH 3 production from the NRR, even though control experiments in Ar and repeated measurements for the catalysts are conducted, because of the ubiquity of ammonia due to its polarity and high aqueous solubility.…”
Section: Nitrogen Fixation At Atomic‐scale Active Sitesmentioning
confidence: 99%
See 1 more Smart Citation