2017
DOI: 10.1016/j.aquaeng.2017.02.004
|View full text |Cite
|
Sign up to set email alerts
|

The use of novel optode sensor technologies for monitoring dissolved carbon dioxide and ammonia concentrations under live haul conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
11
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…However, these disadvantages could be overcome by utilizing an optical chemical sensor (optode) which is based on the optical signal measurements. The membrane optodes have been prepared by immobilizing the indicator (ionophores, chromoionophores, and fluoroionophores) with or without extractant in the solid matrix using highly diversified methods . These sensors are more interested by many researchers and accepted as fast and economical sample monitoring device with an excellent detection limit and sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…However, these disadvantages could be overcome by utilizing an optical chemical sensor (optode) which is based on the optical signal measurements. The membrane optodes have been prepared by immobilizing the indicator (ionophores, chromoionophores, and fluoroionophores) with or without extractant in the solid matrix using highly diversified methods . These sensors are more interested by many researchers and accepted as fast and economical sample monitoring device with an excellent detection limit and sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…CC BY 4.0 License. sensors is the CO2 optode (Atamanchuk et al, 2014) which has been successfully deployed to monitor an artificial CO2 leak on the Scottish west coast (Atamanchuk, et al, 2015b), on a cabled underwater observatory (Atamanchuk, et al, 2015a), to measure lake metabolism (Peeters et al, 2016), for fish transportation (Thomas et al, 2017) and on a moored profiler (Chu et al, 2020).…”
Section: Introductionmentioning
confidence: 99%
“…Contreras-Gutierrez et al also developed a dCO 2 fiber optic sensor using a polymer matrix directly combining a fluorescent dye with the polymer molecule [26]. More recently, Thomas et al added a second dye to extend the fluorescence lifetime from nanoseconds to microseconds, which reduced the cost of the interrogation system used to interrogate only the fluorescence of the first dye [27]. Normally, these are called "wet sensors" [8].…”
Section: Introductionmentioning
confidence: 99%