2021
DOI: 10.3390/ani11041122
|View full text |Cite
|
Sign up to set email alerts
|

The Utility of Intraventricular Pressure Gradient for Early Detection of Chemotherapy-Induced Subclinical Cardiac Dysfunction in Dogs

Abstract: Early detection of doxorubicin (DXR)-induced cardiomyopathy (DXR-ICM) is crucial to improve cancer patient outcomes and survival. In recent years, the intraventricular pressure gradient (IVPG) has been a breakthrough as a sensitive index to assess cardiac function. This study aimed to evaluate the usefulness of IVPG for the early detection of chemotherapy-related cardiac dysfunction. For this purpose, six dogs underwent conventional, speckle tracking, and color M-mode echocardiography concomitantly with pressu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
22
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 11 publications
(25 citation statements)
references
References 51 publications
3
22
0
Order By: Relevance
“…Recent echocardiographic approaches such as two-dimensional speckle tracking echocardiography (2D-STE) and intraventricular pressure gradients (IVPG) calculated from color M-mode echocardiography create a breakthrough in cardiology research for the early diagnosis of cardiac dysfunctions, as compared with other traditional methods [ 16 , 17 , 18 ]. In the present report, the echocardiographic changes were evaluated using conventional echocardiography, 2D-STE and CMME, before and weekly after the implantation of the TEER in two clinically normal dogs.…”
Section: Introductionmentioning
confidence: 99%
“…Recent echocardiographic approaches such as two-dimensional speckle tracking echocardiography (2D-STE) and intraventricular pressure gradients (IVPG) calculated from color M-mode echocardiography create a breakthrough in cardiology research for the early diagnosis of cardiac dysfunctions, as compared with other traditional methods [ 16 , 17 , 18 ]. In the present report, the echocardiographic changes were evaluated using conventional echocardiography, 2D-STE and CMME, before and weekly after the implantation of the TEER in two clinically normal dogs.…”
Section: Introductionmentioning
confidence: 99%
“…This requires the incorporation of novel diagnostic tools used for diastolic function evaluation. Recently, CMME-derived IVPD and IVPG showed breakthroughs in the diagnosis of diastolic dysfunction and are suggested to be included in the conventional echocardiography protocol [9]. In the present study, we studied the response of IVPD and IVPG indices to pharmacologically induced alteration in the loading conditions in rats.…”
Section: Discussionmentioning
confidence: 98%
“…A previous study showed that LV length was positively correlated with IVPD but not associated with IVPG [11]. IVPD was also reported to be sensitive to heart length within a single species [8,9]. As indicated by these reports, it is reasonable to use IVPG in experimental systems to exclude the effect of LV length, especially when the LV length changes due to medication.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations