2017
DOI: 10.1016/j.ejrad.2017.01.029
|View full text |Cite
|
Sign up to set email alerts
|

The value of shear wave elastography in the quantification of corpus cavernosum penis rigidity and its alteration with age

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
19
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(26 citation statements)
references
References 15 publications
7
19
0
Order By: Relevance
“…In previous studies, we tested two-dimensional shear-wave elastography (2-D SWE, ShearWave™ Elastography) for the detection of penile CC tissue stiffness, and found that the obtained values were correlated with age and serum testosterone levels in male volunteers aged from 19 to 81 years old 7. These findings were supported by a recent study by Inci et al ,8 and 2-D SWE showed future potential for evaluating penile CC lesions. Two-dimensional SWE is a new quantitative ultrasound technology that makes the target tissue generate transverse shear waves by ultrasonic pulses.…”
Section: Introductionsupporting
confidence: 72%
“…In previous studies, we tested two-dimensional shear-wave elastography (2-D SWE, ShearWave™ Elastography) for the detection of penile CC tissue stiffness, and found that the obtained values were correlated with age and serum testosterone levels in male volunteers aged from 19 to 81 years old 7. These findings were supported by a recent study by Inci et al ,8 and 2-D SWE showed future potential for evaluating penile CC lesions. Two-dimensional SWE is a new quantitative ultrasound technology that makes the target tissue generate transverse shear waves by ultrasonic pulses.…”
Section: Introductionsupporting
confidence: 72%
“…In a study conducted by Inci et al . the authors drew similar conclusions [44]. Some studies, using sonoelastography on Peyronie’s plaques, reported that sonoelastography provided additional and useful information in detecting penile lesions [42,43].…”
Section: Discussionmentioning
confidence: 64%
“…There are some studies in the literature using elastography, including real-time strain sonoelastography or shear wave elastography (SWE), on penile structure and penile mass, such as Peyronie’s plaques [22,42-44]. Stiffness of the penile cavernous body reflects the changes in tissue structure and composition of corpus cavernosum penis, which includes decreased sinusoids, and this results in occlusion and fibrosis [3,22].…”
Section: Discussionmentioning
confidence: 99%
“…Actually, erectile function strongly depends on the structure of corpus cavernosum (CC) penis besides the vascular and neuronal supply (Inci et al., 2017). Smooth muscle cells and collagen are the main functional density of CCP.…”
Section: Discussionmentioning
confidence: 99%
“…Inci et al. (2017) showed that SWE can provide valuable information as a noninvasive quantitative imaging modality to assess penile structure. In a cohort of 37 healthy subjects, the author also found that the SWE value decreased significantly from Grade 0 to Grade 4 of the erectile hardness (Zheng et al., 2012).…”
Section: Discussionmentioning
confidence: 99%