2001
DOI: 10.1016/s0963-9969(00)00171-x
|View full text |Cite
|
Sign up to set email alerts
|

Thermal and dynamic rheological properties of wheat flour fractions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
25
1

Year Published

2005
2005
2018
2018

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 52 publications
(28 citation statements)
references
References 5 publications
2
25
1
Order By: Relevance
“…On the other hand, peak III appeared at elevated temperatures upon the mixing with Glu or MTGase, suggesting also possible MP/Glu interactions. Neither Glu nor AF alone exhibited any appreciable transition (data not shown), which agreed with Arntfield and Murray (1981), Ma andHarwalkar, 1991, andAddo, Xiong, andBlanchard (2001). It was of interest to note that T max of peak II, which was prominent in all the samples, was not affected (P > 0.05) by MTGase nor by the non-muscle proteins.…”
Section: Thermal Propertiessupporting
confidence: 60%
“…On the other hand, peak III appeared at elevated temperatures upon the mixing with Glu or MTGase, suggesting also possible MP/Glu interactions. Neither Glu nor AF alone exhibited any appreciable transition (data not shown), which agreed with Arntfield and Murray (1981), Ma andHarwalkar, 1991, andAddo, Xiong, andBlanchard (2001). It was of interest to note that T max of peak II, which was prominent in all the samples, was not affected (P > 0.05) by MTGase nor by the non-muscle proteins.…”
Section: Thermal Propertiessupporting
confidence: 60%
“…The starch granules, which mainly contain amylopectin, initially entrapped simply as filler in the gluten network (Hagenimana et al, 2005). It reinforces this network as they began to swell and distort upon heating; and then rupture into an amylose matrix, forming a gel (Angioloni and Dalla, 2005;Addo et al, 2001;Che et al, 2007;Lai and Kokini, 1991;Olkku and Rha, 1978). Because of the starch gelatinization, which commence approximately at 50°C, the G 0 and G 00 of the control sample at 80°C were higher than those of the control sample at 25°C.…”
Section: Resultsmentioning
confidence: 99%
“…The lower, serrated plate was set at 30°C and used in conjunction with a 25 mm upper plate. The upper plate was lowered to 1.025 mm, the sample was trimmed and a layer of mineral oil applied to avoid desiccation (Addo, Xiong, & Blanchard, 2001;Létang, Piau, & Verdier, 1999). The sample was brought to a final gap of 1 mm and subjected to further 10 min rest to allow any additional loading stresses to dissipate.…”
Section: Fundamental Rheologymentioning
confidence: 99%