“…Equation (19) shows that the basic rating life, L 10 , is proportional to the functions φ and ω 10 . From (21) we see that, for given radial load F r , function φ increases more than quadratically with the filling ratio, ζ, and the aspect ratio, λ, and goes up with the sixth power of the pitch diameter, D. Function φ can be regarded as a control factor through which the basic rating life, L 10 , can easily be made large at will by increasing the pitch diameter.…”