Abstract:The paper deals with the process properties in terms of the heat transfer, i.e. the thermal performance of the thermal-process units within a helium loop intended for the testing of the decay heat removal (DHR) from the model of the gas-cooled fast reactor (GFR). The system is characterised by a natural circulation of helium, as a coolant, and assume the steady operating conditions of the circulation. The helium loop consists of four main components: the model of the gas-cooled fast reactor, the model of the h… Show more
“…For this reason, the research of helium cooling loop systems is very topical. The research activities in the given area from several aspects are documented in the various publications, as for example [1,2,3,4,5,6,7,8,9,10].…”
Section: Introductionmentioning
confidence: 99%
“…This cooling loop can be defined as a model of passive safety feature serving to emergency heat removal from the fast reactor working space (the active zone of gas-cooled fast reactor). Such a type of helium cooling loop is one of the research subjects in our department [4,7,9].…”
The paper presents a comparison of the process properties of two types of the heat exchangers designed for the heat removal from a high temperature helium cooling loop with steady natural circulation of helium. The first considered heat exchanger is a shell and tube heat exchanger with U-tubes and the other one is a helical coil heat exchanger. Using the thermal and hydrodynamic process calculations, the thermal performance of the two alternative heat exchangers are determined, as well as the pressure drops of flowing fluids in their workspaces. The calculations have been done for several defined operating conditions of two considered types of heat exchangers. The operating conditions of heat exchangers correspond to the certain helium flow rates.
“…For this reason, the research of helium cooling loop systems is very topical. The research activities in the given area from several aspects are documented in the various publications, as for example [1,2,3,4,5,6,7,8,9,10].…”
Section: Introductionmentioning
confidence: 99%
“…This cooling loop can be defined as a model of passive safety feature serving to emergency heat removal from the fast reactor working space (the active zone of gas-cooled fast reactor). Such a type of helium cooling loop is one of the research subjects in our department [4,7,9].…”
The paper presents a comparison of the process properties of two types of the heat exchangers designed for the heat removal from a high temperature helium cooling loop with steady natural circulation of helium. The first considered heat exchanger is a shell and tube heat exchanger with U-tubes and the other one is a helical coil heat exchanger. Using the thermal and hydrodynamic process calculations, the thermal performance of the two alternative heat exchangers are determined, as well as the pressure drops of flowing fluids in their workspaces. The calculations have been done for several defined operating conditions of two considered types of heat exchangers. The operating conditions of heat exchangers correspond to the certain helium flow rates.
There are the various types of heat exchangers. The selection of the heat exchanger right type is the first basic assumption for its optimal operation. The heat exchanger calculation itself is another prerequisite for its optimal operation. This article deals with the variables which are usually used to describe the stationary operation of any recuperative heat exchanger with two incoming and two outgoing streams. The knowledge of these variables, including the facts resulting from them, is necessary not only from the point of view of the calculation but also from the point of view of the evaluation of the experimental data of any heat exchanger. The variables values needed for the calculation of heat exchangers, so-called key variables, must always fall within the values range determined on the basis of generally valid knowledge about heat exchangers. The article also deals with the determination of the limit values defining the values range of these key variables.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.