2018
DOI: 10.1016/j.conbuildmat.2018.03.162
|View full text |Cite
|
Sign up to set email alerts
|

Thermal conductivity measurement of thermal insulating mortars with EPS and silica aerogel by steady-state and transient methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
21
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(25 citation statements)
references
References 39 publications
3
21
0
1
Order By: Relevance
“…However, this behaviour can be explained by an extra curing effect caused by freezing/thawing cycles due to the Na + [59,60] that compensate to some extent the external degradation. These results meet the study of Zhang & Gjorv [61] (as quoted by [62]) that obtained equal or even better durability for lightweight aggregate concrete than standard concrete, even when subjected to severe conditions.…”
Section: Freeze/thaw Accelerated Agingsupporting
confidence: 91%
See 1 more Smart Citation
“…However, this behaviour can be explained by an extra curing effect caused by freezing/thawing cycles due to the Na + [59,60] that compensate to some extent the external degradation. These results meet the study of Zhang & Gjorv [61] (as quoted by [62]) that obtained equal or even better durability for lightweight aggregate concrete than standard concrete, even when subjected to severe conditions.…”
Section: Freeze/thaw Accelerated Agingsupporting
confidence: 91%
“…The Young's modulus was determined according to ASTM E 1876-1 [80], through the resonant frequency of the flexural vibration mode obtained with the equipment GrindoSonic MK5 "Industrial". The thermal conductivity was evaluated by the transient method with the ISOMET 2114 device, in line with ASTM D 5930 [81], and was considered as suitable method for testing in small scale samples [62]. These properties were evaluated before and after aging tests.…”
Section: Methodsmentioning
confidence: 99%
“…Research works (laboratory) Silica aerogel [25,[65][66][67][68][69][70][71][72][73] S1 to S9 Research works (semi-industrial) Silica aerogel with others [25,[66][67][68][69] I1 to I21 Industrial product (industrial) EPS, cork, perlite, silica aerogel [74][75][76][77][78][79][80][81][82][83][84] Although all calculation procedures being widely known and easily found in statistics literature [85,86], their implementation using statistical software makes its analysis more complete. Therefore, all data was inserted into an Excel data matrix.…”
Section: L1 To L5mentioning
confidence: 99%
“…Santa et al [10] usan un dispositivo para medir la conductividad térmica en materiales aislantes por el método de placa guardada. Gomes et al [11] usan dos métodos para comparar sus resultados: régimen estacionario y transitorio, obteniendo diferentes resultados con ambos métodos. Buratti et al [7] desarrollaron un equipo consistente en una caja con un panel caliente y otro frío, para caracterizar materiales compuestos obteniendo valores del CT en rangos adecuados para considerarlos como aislantes térmicos prometedores en remodelación de edificios.…”
Section: Ingeniería Y Cienciaunclassified