2013 IEEE International 3D Systems Integration Conference (3DIC) 2013
DOI: 10.1109/3dic.2013.6702362
|View full text |Cite
|
Sign up to set email alerts
|

Thermal correlation between measurements and FEM simulations in 3D ICs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…where T is the temperature, a is the ellipse parameter, and β is a parameter fixed to 0.5 [5], determined by optimizing the model. To have the most predictive numerical model possible in relation to 150 runs of DOE, the choice to model the behavior of the temperature with a hyperbolic function was done.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…where T is the temperature, a is the ellipse parameter, and β is a parameter fixed to 0.5 [5], determined by optimizing the model. To have the most predictive numerical model possible in relation to 150 runs of DOE, the choice to model the behavior of the temperature with a hyperbolic function was done.…”
Section: Resultsmentioning
confidence: 99%
“…In this paper, the top heat-transfer coefficient is fixed at 8 W/(m 2 · K), which models natural convection with air. Note that this quite low value limits the heat dissipation and does not have impact on trends [5]. …”
Section: B Sensitivity Studymentioning
confidence: 98%
See 2 more Smart Citations
“…The first step is to reproduce the measured thermal response to the steady and pulsed power inputs, according to the TCAD model calculation with the finite element method [21]. We calibrate the convective boundary conditions based on the measured thermal response to the steady power input.…”
Section: Thermal Modeling Methodologymentioning
confidence: 99%