2015
DOI: 10.1155/2015/367632
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Performance Analysis of Reinforced Concrete Floor Structure with Radiant Floor Heating System in Apartment Housing

Abstract: The use of the resilient materials in the radiant floor heating systems of reinforced concrete floor in apartment housing is closely related to the reduction of the floor impact sound and the heating energy loss. This study examined the thermal conductivity of expanded polystyrene (EPS) foam used for the resilient material in South Korea and analysed the thermal transfer of reinforced concrete floor structure according to the thermal conductivity of the resilient materials. 82 EPS specimens were used to measur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…Contrary to PU/PRG foams, PU/GL foams are characterized by the reducing thermal conductivity. It might be explained by the increasing density and, accordingly, decreasing radiant heat transfer via trapped gases in smaller foam cells in the higher density foams (Jeong, Jung 2015). As can be seen from Figure 1c, PU/ ST foams have almost the same thermal conductivity value independently from the ST content used.…”
Section: Thermal Conductivity and Cell Sizementioning
confidence: 84%
“…Contrary to PU/PRG foams, PU/GL foams are characterized by the reducing thermal conductivity. It might be explained by the increasing density and, accordingly, decreasing radiant heat transfer via trapped gases in smaller foam cells in the higher density foams (Jeong, Jung 2015). As can be seen from Figure 1c, PU/ ST foams have almost the same thermal conductivity value independently from the ST content used.…”
Section: Thermal Conductivity and Cell Sizementioning
confidence: 84%
“…According to Jeong & Jung (2015), the heating system with hydraulic underfloor heating needs a longer pre-heating time to reach the desired temperature, as compared with the heating system with electric underfloor heating.…”
Section: Figurementioning
confidence: 99%
“…is type of concrete is a new type of geotechnical material developed in recent years and possesses the advantages of low weight, stable performance, convenient construction, and so forth. [4][5][6][7]. e applications of cast-in-situ foamed concrete have expanded considerably in civil engineering as a result of scientific and technical advances in its production.…”
Section: Introductionmentioning
confidence: 99%