2020
DOI: 10.1002/er.4966
|View full text |Cite
|
Sign up to set email alerts
|

Thermal performance of a solar‐assisted heat pump drying system with thermal energy storage tank and heat recovery unit

Abstract: Summary Thermal performance parameters for a solar‐assisted heat pump (SAHP) drying system with underground thermal energy storage (TES) tank and heat recovery unit (HRU) are investigated in this study. The SAHP drying system is made up of a drying unit, a heat pump, flat plate solar collectors, an underground TES tank, and HRU. An analytical model is developed to obtain the performance parameters of the drying system by using the solution of heat transfer problem around the TES tank and energy expressions for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 40 publications
0
8
0
Order By: Relevance
“…Specific energy consumption (SEC) and specific moisture extraction rate (SMER) are two of the most utilized metrics to evaluate the effectiveness of a dehumidificator and can be obtained by using Equations ( 12) and ( 13), respectively 51 :…”
Section: Theoretical Analysismentioning
confidence: 99%
“…Specific energy consumption (SEC) and specific moisture extraction rate (SMER) are two of the most utilized metrics to evaluate the effectiveness of a dehumidificator and can be obtained by using Equations ( 12) and ( 13), respectively 51 :…”
Section: Theoretical Analysismentioning
confidence: 99%
“…The average values of the COP for the simple‐HPD with open loop, simple‐HPD with closed‐loop, WHR‐assisted HPD in open, and WHR‐assisted HPD in closed systems were 5.34, 4.25, 5.18, and 3.48, respectively. COP values for closed‐loop are in the literature range; however, COP of open‐loop was a little high as compared to closed‐loop as most of the researchers did the experiment in the closed‐loop (Ismaeel & Yumrutaş, 2020; Shah et al., 2016; Wang et al., 2019).…”
Section: Resultsmentioning
confidence: 99%
“…Atalay (2019) experimentally investigated the exergoeconomic performance of solar drying and HPD systems separately and found a minimum exergoeconomic factor of 0.514 and 0.045, respectively. Ismaeel and Yumrutaş (2020) investigated the thermal performance of the solar‐assisted HPD with underground energy storage and heat recovery and found the SMER of 9.25 kg/kWh.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, the storage and transport, and metering of crude oil do not pay much attention to the temperature change and stress state of the crude oil in storage tank [1][2][3]. The accurate metering of crude oil relies on the precision of temperature measurement [4][5][6].…”
Section: Introductionmentioning
confidence: 99%