Thermal Analysis 1980
DOI: 10.1007/978-3-0348-6736-8_74
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Studies on Flame Retardation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1982
1982
1987
1987

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…The curves of the same sample obtained by sparking are demonstrated on Fig. 23b Simon et al [114] also reported the advantage of thermo-analytical techniques in flame retardation research from theoretical and practical point of view. The reaction between cellulose and the FR was seen in the DTG curve at 180 ~ The thermal stability was slightly decreased, but at higher temperature the TG curve of the treated sample always was above that of the non-treated sample.…”
Section: Fig 1 Curing Study Of a Commercial Resinmentioning
confidence: 88%
See 1 more Smart Citation
“…The curves of the same sample obtained by sparking are demonstrated on Fig. 23b Simon et al [114] also reported the advantage of thermo-analytical techniques in flame retardation research from theoretical and practical point of view. The reaction between cellulose and the FR was seen in the DTG curve at 180 ~ The thermal stability was slightly decreased, but at higher temperature the TG curve of the treated sample always was above that of the non-treated sample.…”
Section: Fig 1 Curing Study Of a Commercial Resinmentioning
confidence: 88%
“…Simon et al [113] applied a derivatograph in flame retardation research in determining ignition temperature. The study was aimed at modifying the derivatograph for the measurement of the flash ignition and self-ignition temperature of various materials and to combine these characteristic data with the simultaneously measured TG, DTG and DTA curves.…”
Section: Fig 1 Curing Study Of a Commercial Resinmentioning
confidence: 99%
“…We performed our experiments in two ways: in a hot-air furnace heated by a hot air stream, and in a modified derivatograph [1]. As the modified derivatograph is a newly-developed instrument, the optimum experimental conditions for textile investigations were not known.…”
Section: Methodsmentioning
confidence: 99%
“…New Techniques, Miscellaneous Techniques. The derivatograph was used for the measurement of flash ignition and self-ignition temperatures of solid materials and for the combination of these with TG, DTG, and DTA (205). An ignition test for plastic films >6 mm thick used an apparatus consisting of a burner with a controlled pilot flame upon which a sample support plate and movable heat shield was fastened (104).…”
Section: Miscellaneous Thermal Analysis Techniquesmentioning
confidence: 99%