2015
DOI: 10.1016/j.enbuild.2015.01.068
|View full text |Cite
|
Sign up to set email alerts
|

Thermal uniformity in an open plan room with an active chilled beam system and conventional air distribution systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
20
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(21 citation statements)
references
References 14 publications
1
20
0
Order By: Relevance
“…However, there are not enough well-defined regulations specific to chilled beams in Korea. Thus, as a reference, we used the REHVA standard and the results of previous studies [78][79][80] that verified the energy-saving effect of chilled beams in Korean climate to set the entrance temperature for hot-cool water. We installed the most common two-way diffusion chilled beam, and we used the outdoor air pre-processed by the DOAS as a primary air for the chilled beam [77].…”
Section: Selection Of Active Systems (Cases 6-13)mentioning
confidence: 99%
“…However, there are not enough well-defined regulations specific to chilled beams in Korea. Thus, as a reference, we used the REHVA standard and the results of previous studies [78][79][80] that verified the energy-saving effect of chilled beams in Korean climate to set the entrance temperature for hot-cool water. We installed the most common two-way diffusion chilled beam, and we used the outdoor air pre-processed by the DOAS as a primary air for the chilled beam [77].…”
Section: Selection Of Active Systems (Cases 6-13)mentioning
confidence: 99%
“…If the Beta distribution applies, it may be possible to quantify the characteristic curves in Figure 1 for various situations mathematically based on the general model of the Beta distribution. This paper first introduces the Beta distribution and its background theory of the order statistics, then validates the findings by the measurement data of the five warehouse and storage spaces, 20 and eleven published studies [5][6][7][8][9][10][11]13,15,23,38 from the literature. This paper also discusses a few practical implications and applications of these findings.…”
Section: Practical Implicationsmentioning
confidence: 69%
“…In buoyancy-driven ventilated spaces including displacement [5][6][7] and/or underfloor ventilation systems, [8][9][10][11][12] and natural ventilation in large spaces 13,14 during cooling seasons; and 3). In buoyancy-driven ventilated spaces including displacement [5][6][7] and/or underfloor ventilation systems, [8][9][10][11][12] and natural ventilation in large spaces 13,14 during cooling seasons; and 3).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The performance of these systems is extensively analyzed in various recent studies. Most of the research is based on either computer simulations, mainly computational fluid dynamics (CFD) studies or studies conducted in controlled laboratory environments [26][27][28][29][30][31][32][33][34][35][36][37][38][39][40]. The research in real office settings is mainly focused on buildings located in warm and hot climate countries, dominated by cooling need [41][42][43][44].…”
Section: Introductionmentioning
confidence: 99%