This study investigated the impact of thermally improved spacers (TISs) on the condensation prevention and energy saving performances of residential windows. The temperature factor and total U-value were analyzed with the two-box model, by which the TISs are represented with the equivalent thermal conductivity. The results showed that the TISs could increase the temperature factor by up to 12%, and this significantly improved the condensation prevention performance. In addition, it was proved that the TIS enables the prevention of the condensation at an outdoor temperature that is 4.2 • C to 15.7 • C lower compared with the conventional spacer. Also, it was shown that the TISs reduce the total U-value by an amount from 0.07 W/m 2 K to 0.12 W/m 2 K, implying that the heat loss through the window is reduced by a rate from 2.8% to 8.2%. In addition, the results of the whole building energy simulation proved that the TISs can reduce the annual heating-energy consumption by a rate from 3.0% to 6.3%. The results were then used for the development of monographs to determine the equivalent thermal conductivity of a window spacer that can meet the performance criteria in terms of condensation prevention and energy saving.
Ceiling radiant cooling panel (CRCP) systems are being increasingly applied to commercial buildings due to their high thermal comfort level and energy efficiency. It is recommended that CRCP systems should be operated at a relatively high chilled water temperature to prevent condensation and save energy. However, even though a high chilled water temperature is effective for achieving condensation-free operation and high chiller efficiency, it can lead to insufficient cooling capacity. In this study, a method of enhancing the cooling capacity of CRCP systems was investigated through mock-up chamber tests. The open-type installation of CRCPs and the combination of air circulators were used to enhance the cooling capacity and energy performance of CRCP systems. Experimental results showed that compared to a conventional CRCP system, the cooling capacity of an open-type CRCP system with air circulators increased by up to 26.2%, and its cooling energy consumption decreased by up to 26.4%. Additionally, the open-type CRCP system with air circulators reduced the difference between the room air temperature and mean chilled water temperature. Thus, the proposed system can operate at a relatively high chilled water temperature, which is effective for reducing condensation risk and cooling energy consumption.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.