2000
DOI: 10.1088/0954-0083/12/3/302
|View full text |Cite
|
Sign up to set email alerts
|

Thermo-Processable Polyimides with High Thermo-Oxidative Stability as Derived from Oxydiphthalic Anhydride and Bisphenol a Type Dianhydride

Abstract: Two series of homopolyimides based on oxydiphthalic anhydride and bisphenol A bisether-4-diphthalic anhydride were synthesized with 12 kinds of aromatic diamines. Several thermo-processable homopolyimides were the focus of further investigation. The structureproperty relationships of these homopolyimides were examined as functions of the glass transition temperature (T g ), melting point (T m ), thermal decomposition temperature (T d ), and meltflowability. The effects of the chemical and higher-order structur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
40
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 53 publications
(40 citation statements)
references
References 16 publications
0
40
0
Order By: Relevance
“…This can be interpreted in terms of suppressed internal rotation of the central hydroquinone moiety by some steric hindrance due to the present small substituents. If another more bulky substituent (such as phenyl group) were incorporated instead of the present methyl and methoxy groups, a decrease in T g would be caused as speculated from our previous data 35 that T g = 236 C for non-substituted ODPA/TPEQ and T g = 212 C for phenyl-substituted ODPA/PTPEQ where ODPA = oxydiphthalic anhydride, TPEQ = 1,4-bis(4-aminophenoxy)benzene, PTPEQ = 1,4-bis(4-aminophenoxy)-2-phenylbenzene. The present TAHQ series/4,4 0 -ODA systems also showed much higher CTE values ranging 47.1 to 51.2 ppm/K in addition to much lower tensile modulus than the rigid PEsI systems mentioned above, as predicted from their non-linear backbone structures but still lower than the values of common flexible PI systems (usually 60-80 ppm/K).…”
Section: Molecular Designmentioning
confidence: 77%
“…This can be interpreted in terms of suppressed internal rotation of the central hydroquinone moiety by some steric hindrance due to the present small substituents. If another more bulky substituent (such as phenyl group) were incorporated instead of the present methyl and methoxy groups, a decrease in T g would be caused as speculated from our previous data 35 that T g = 236 C for non-substituted ODPA/TPEQ and T g = 212 C for phenyl-substituted ODPA/PTPEQ where ODPA = oxydiphthalic anhydride, TPEQ = 1,4-bis(4-aminophenoxy)benzene, PTPEQ = 1,4-bis(4-aminophenoxy)-2-phenylbenzene. The present TAHQ series/4,4 0 -ODA systems also showed much higher CTE values ranging 47.1 to 51.2 ppm/K in addition to much lower tensile modulus than the rigid PEsI systems mentioned above, as predicted from their non-linear backbone structures but still lower than the values of common flexible PI systems (usually 60-80 ppm/K).…”
Section: Molecular Designmentioning
confidence: 77%
“…The introduction of flexible linkage diamines significantly decreases the T g such as TPER and TPEQ contrary to the effect of more . This phenomenon can be attributed to the PIs with meta linkages disturb the intimate chain stacking necessary for intermolecular interaction [5]. As a result, the introduction of meta-linkages causes a significant decrease in T g .…”
Section: Basic Properties Of Homopolyimidesmentioning
confidence: 99%
“…For instance, commercial thermoplastic polyimide Ultem possesses excellent melt processability but its longterm service temperature is limited to lower than 170°C. Moreover, the thermoxidative stability of Ultem is also relatively poor because of the presence of thermally unstable isopropylidene groups in the polymer backbones [5]. Thermoplastic PIs are commonly applied in various industries because of the ease of processing, handling, and storage.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations