2017
DOI: 10.1016/j.trac.2017.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Third order chromatographic-excitation–emission fluorescence data: Advances, challenges and prospects in analytical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
15
0
3

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 43 publications
0
15
0
3
Order By: Relevance
“…Cabe señalar que la correcta elección del algoritmo para el modelado de estos datos es crítica y depende de la propiedad de multilinealidad generada en cada estrategia. 50,51 De acuerdo a sus características de multilinealidad, los datos de tercer orden pueden clasificarse en las siguientes categorías:…”
Section: Datos Cromatográficos De Tercer Ordenunclassified
See 2 more Smart Citations
“…Cabe señalar que la correcta elección del algoritmo para el modelado de estos datos es crítica y depende de la propiedad de multilinealidad generada en cada estrategia. 50,51 De acuerdo a sus características de multilinealidad, los datos de tercer orden pueden clasificarse en las siguientes categorías:…”
Section: Datos Cromatográficos De Tercer Ordenunclassified
“…c_ Datos no-cuadrilineales tipo 4 (donde hay correlación entre dos o más modos). 51,52 En los datos obtenidos con la estrategia 1…”
Section: Datos Cromatográficos De Tercer Ordenunclassified
See 1 more Smart Citation
“…In the latter case, the approach consists in recording EEFMs as a function of the elution time; the main issue is to find adequate experimental and instrumental conditions that allow obtaining an adequate number of EEFMs containing satisfactory information in a short time. Very recently, Montemurro et al described analytical methodologies for the generation of third-order LC-EEFM data [8]. The authors discussed the following suitable strategies: (1) injecting the sample several times and recording the emission wavelength-elution time matrix, each time at a different excitation wavelength [9,10], and (2) collecting elution fractions at the end of the chromatographic procedure every few seconds, and then measuring EEFMs for each collected aliquot [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Although this is the most attractive one, since neither flow interruption nor fraction collection are required, it was deficient in the mode in which it was implemented. This is due to the presence of strong dependence between the phenomena corresponding to the excitation and time modes [8].…”
Section: Introductionmentioning
confidence: 99%