2017
DOI: 10.1016/j.ijom.2016.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional printed final occlusal splint for orthognathic surgery: design and validation

Abstract: Please cite this article in press as: Shaheen E, et al. Abstract. Orthognathic surgery is indicated for the treatment of significant skeletal malocclusion and is normally prepared using conventional face bows combined with two-dimensional cephalometric analysis and manually made splints. With recent developments in oral imaging, more orthognathic surgeries are being planned using three-dimensional computer-aided design and manufacturing (3D CAD/ CAM) software. The purpose of this study was to present a protoco… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
60
0
11

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
3
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 104 publications
(71 citation statements)
references
References 11 publications
0
60
0
11
Order By: Relevance
“…After this fatigue phase, the specimens were placed in the Instron Universal Testing machine (E3366, Instron, MA, America). Each tooth was loaded at the central fossa at 135° from the tooth long axis to simulate a maximum bending motion of the tooth at buccal cervical areas [8]. A continuous compressive force was applied with a 2-mm spherical crosshead at 1 mm/min until failure occurred, which was de ned as a 25% drop in the applied force [24] ( Fig.…”
Section: Load At Fracturementioning
confidence: 99%
“…After this fatigue phase, the specimens were placed in the Instron Universal Testing machine (E3366, Instron, MA, America). Each tooth was loaded at the central fossa at 135° from the tooth long axis to simulate a maximum bending motion of the tooth at buccal cervical areas [8]. A continuous compressive force was applied with a 2-mm spherical crosshead at 1 mm/min until failure occurred, which was de ned as a 25% drop in the applied force [24] ( Fig.…”
Section: Load At Fracturementioning
confidence: 99%
“…Bu yöntemle üretilen splintlerin oklüzal yüzeylerle uyumlarının daha yüksek olduğu bildirilmiştir. 67 Kanin koruyuculu oklüzyona sahip splintlerin temporomandibuler semptomları azaltmada bilateral balanslı oklüz-yonda hazırlanan splintlere göre daha etkili olduğu belirtilmiştir. 68,69 Oklüzal splintler yeni protezle sağlanacak oklüzal dikey boyuta ve oluşacak yeni mandibuler harekete hastanın daha kolay adapte olması amacıyla kullanılabilmektedir.…”
Section: Posteri̇or Isirma Plağiunclassified
“…Some surgeries can be planned using threedimensional computer aided design and manufacturing (3D CAD/CAM) software. e 3D virtual planning is performed in PROPLAN software and exported into 3-matic software to design and then use the biocompatible material to print [12]. Shaheen et al and Rengier and Mehndiratta used dedicated postprocessing algorithm to extract a spatial model from image data sets and export to machine-readable data [12,13].…”
Section: Introductionmentioning
confidence: 99%