Three-Dimensional Super-Resolution Imaging Using a Row–Column Array

Abstract: A 3-D super resolution (SR) pipeline based on data from a Row-Column (RC) array is presented. The 3 MHz RC array contains 62 rows and 62 columns with a half wavelength pitch. A Synthetic Aperture (SA) pulse inversion sequence with 32 positive and 32 negative row emissions are used for acquiring volumetric data using the SARUS research ultrasound scanner. Data received on the 62 columns are beamformed on a GPU for a maximum volume rate of 156 Hz, when the pulse repetition frequency is 10 kHz. Simulated and 3-D … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
35
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
3
1

Relationship

2
6

Authors

Journals

citations
Cited by 53 publications
(37 citation statements)
references
References 44 publications
1
35
0
1
Order By: Relevance
“…The 3D reconstructions give a more complete morphological examination, but do not allow MB tracking in the elevational plane or motion compensation in all three directions. This could become feasible with other types of probes, e.g., row-column and matrix ultrasound probes that are currently being developed for in vivo SR imaging [ 54 , 55 , 56 ].…”
Section: Discussionmentioning
confidence: 99%
“…The 3D reconstructions give a more complete morphological examination, but do not allow MB tracking in the elevational plane or motion compensation in all three directions. This could become feasible with other types of probes, e.g., row-column and matrix ultrasound probes that are currently being developed for in vivo SR imaging [ 54 , 55 , 56 ].…”
Section: Discussionmentioning
confidence: 99%
“…The full volume was beamformed continuously, and the envelope signal was processed in a 3-D super resolution pipeline for bubble detection and presentation. A precision of roughly 20 µm was attained in all three coordinates in the full volume [83].…”
Section: From 2-d To 4-dmentioning
confidence: 99%
“…Three-dimensional super resolution of of 3-D printed micro-phantom with a 200 µm diameter channel. The blue dots each indicate a single detected bubble (from[83]). …”
mentioning
confidence: 99%
“…In total 640 volumetric frames were acquired over 640 positions. The volumetric frames were then passed to the SRI pipeline [13].…”
Section: B Experimental Setup and Proceduresmentioning
confidence: 99%
“…The coordinates can then be collected across all imaged frames to form tracks. The pipeline was implemented in MATLAB, and processing was performed offline [13]. Fig.…”
Section: Super-resolution Pipelinementioning
confidence: 99%