2021
DOI: 10.1016/j.epsr.2021.107058
|View full text |Cite
|
Sign up to set email alerts
|

Three-phase modeling of 40.5-kV vacuum circuit breaker switching off shunt reactors and overvoltage suppression measure analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 22 publications
0
10
0
Order By: Relevance
“…Due to the complexity of the operating conditions of shunt reactors, the uncertainty of the health state development, the fuzziness between the state levels, and other problems, a processing method based on the Gaussian Cloud Model (GCM) can be established. The certainty of cloud drops is the bridge between cloud drops and qualitative concept C, reflecting fuzziness [16][17][18] . The value of certainty is also a random value, which can be described by the probability distribution function.…”
Section: Multi-information Fusion Methodsmentioning
confidence: 99%
“…Due to the complexity of the operating conditions of shunt reactors, the uncertainty of the health state development, the fuzziness between the state levels, and other problems, a processing method based on the Gaussian Cloud Model (GCM) can be established. The certainty of cloud drops is the bridge between cloud drops and qualitative concept C, reflecting fuzziness [16][17][18] . The value of certainty is also a random value, which can be described by the probability distribution function.…”
Section: Multi-information Fusion Methodsmentioning
confidence: 99%
“…These overvoltages can potentially damage equipment, cause insulation breakdown, and compromise the reliability of the system [19]. The (1) indicates that as the chopped current level rises, both the stored energy and chopping voltage increase. Moreover, it's evident that current chopping significantly affects reactors with lower stray capacitance.…”
Section: Current Choppingmentioning
confidence: 99%
“…A shunt reactor is a type of electrical device used in power systems to compensate for reactive power. Reactive power is the power that oscillates between the generation and consumption of electric energy due to the presence of inductive or capacitive elements in the system [1]- [4]. Shunt reactors are specifically designed to consume or produce reactive power, the reactor bank should be switched off during periods of high load on the transmission line, based on the power system's needs [5], [6].…”
Section: Introductionmentioning
confidence: 99%
“…Since the stray capacitance of SR has a significant impact on the chopping overvoltage, both the phase‐to‐ground capacitances ( C A , C B , and C C ) and the inter‐phase capacitances ( C AB , C BC , and C CA ) should be considered. The values are set as 1500 pF in our case [27].…”
Section: Modelling Of Offshore Wind Farmmentioning
confidence: 99%