2009
DOI: 10.1016/j.ajo.2009.03.027
|View full text |Cite
|
Sign up to set email alerts
|

Three-Year Follow-up of Posterior Capsule Opacification After AquaLase and NeoSoniX Phacoemulsification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 24 publications
1
10
0
Order By: Relevance
“…The previous results of this study after 1, 2 and 3-year follow-up have been published 12 . In order to investigate whether the difference in PCO rates after AquaLase and NeoSoniX phacoemulsification was consistent over longer period of time, an 8-year follow-up was performed.…”
Section: Introductionmentioning
confidence: 70%
See 2 more Smart Citations
“…The previous results of this study after 1, 2 and 3-year follow-up have been published 12 . In order to investigate whether the difference in PCO rates after AquaLase and NeoSoniX phacoemulsification was consistent over longer period of time, an 8-year follow-up was performed.…”
Section: Introductionmentioning
confidence: 70%
“…Study design, image acquisition, and computer analysis of PCO, as well as the statistical methods and sample size calculation used, were exactly the same as in our previous publication 12 . Thirty-seven patients of the original 62 were included in the study.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…2,[27][28][29] The mean values of Total PCO score in a two-year follow-up calculated according to the EPCO system in the case of IOLs constructed on the basis of AcrySof platform are low and are within the limit from 0.145 to 0.478. 30,31 The calculated in the same way values for PMMA IOLs covered with heparin (809C, Pharmacia&Upjohn) were 0.741, for hydrophilic acryl IOLs (Centerflex 570H, Rayner) 0.78, whereas for silicone IOLs (SI-40NB, Allergan) 1.807. 10,30 It should be noted that IOLs 809C (Pharma&Upjohn) and SI-40NB (Allergan) have round-edged optics, which undoubtedly is the main cause of higher values of Total PCO score, 27,28,[32][33][34] whereas in the case of Centerflex 570H (Rayner) IOLs with sharp-edged optics the material from which they are constructed can play a role.…”
Section: Discussionmentioning
confidence: 99%
“…30,31 The calculated in the same way values for PMMA IOLs covered with heparin (809C, Pharmacia&Upjohn) were 0.741, for hydrophilic acryl IOLs (Centerflex 570H, Rayner) 0.78, whereas for silicone IOLs (SI-40NB, Allergan) 1.807. 10,30 It should be noted that IOLs 809C (Pharma&Upjohn) and SI-40NB (Allergan) have round-edged optics, which undoubtedly is the main cause of higher values of Total PCO score, 27,28,[32][33][34] whereas in the case of Centerflex 570H (Rayner) IOLs with sharp-edged optics the material from which they are constructed can play a role. 2,31,35 Thus, the severity of PCO depends on many factors and methods of LEC proliferation prevention.…”
Section: Discussionmentioning
confidence: 99%