2022
DOI: 10.4244/eij-d-21-00734
|View full text |Cite
|
Sign up to set email alerts
|

Three-year outcomes of transcatheter aortic valve implantation for bicuspid versus tricuspid aortic stenosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
19
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 31 publications
2
19
0
Order By: Relevance
“…Thus, since CAVD is highly correlated with age particularly among individuals over 70 years, emerging TAVR brought good news to these patients. In research, enrolling 246 consecutive AS patients who underwent TAVR, obvious hemodynamics improvement of the aortic valve and cardiac reverse remodeling were observed after a 3-year follow-up ( 29 ). Therefore, TAVR significantly improved the living qualities and reduced disabilities caused by CAVD, especially for patients with advanced ages.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, since CAVD is highly correlated with age particularly among individuals over 70 years, emerging TAVR brought good news to these patients. In research, enrolling 246 consecutive AS patients who underwent TAVR, obvious hemodynamics improvement of the aortic valve and cardiac reverse remodeling were observed after a 3-year follow-up ( 29 ). Therefore, TAVR significantly improved the living qualities and reduced disabilities caused by CAVD, especially for patients with advanced ages.…”
Section: Discussionmentioning
confidence: 99%
“…Hangzhou Solution procedural strategy was used to decide prosthesis size selection in bicuspid aortic valve stenotic patients [ 10 , 11 ]. Other details of procedural strategy can be found in our previous studies [ 12 , 13 ]. The clinical adverse events were defined following the Valve Academic Research Consortium-2 consensus [ 14 ].…”
Section: Methodsmentioning
confidence: 99%
“…Left ventricular ejection fraction (LVEF) estimated by the two-dimensional methods was 61.4%. Multi-detected CT (MDCT) identified that the aortic valve was bicuspid aortic valve type 1 and a raphe with a bulky calcification between the left and non-coronary sinuses ( 4 , 5 ). Further anatomical measurements on MDCT included an annular perimeter of 73.1 mm, an annular area of 414.1 mm 2 , and the left main coronary artery (LMA) ostium height of 11 mm and right coronary artery (RCA) of 14.1 mm ( Figures 1A,B,D,E ).…”
Section: Case Presentationmentioning
confidence: 99%
“…The procedure was performed in our hybrid operating room for TAVR as previously described ( 4 ). At the beginning of the TAVR procedure, bilateral coronary arteries were patent under intraoperative fluoroscopy ( Figure 2A ).…”
Section: Case Presentationmentioning
confidence: 99%