1995
DOI: 10.1002/jcu.1870230306
|View full text |Cite
|
Sign up to set email alerts
|

Thyroid nodules: Re‐evaluation with ultrasound

Abstract: The purpose of this study was to clarify ultrasound (US) evaluation of microcalcifications and determine whether the calcifications seen in US scans can reliably predict malignant thyroid tumors. Diagnostic accuracy of microcalcification and other various signs seen in US scans for predicting malignancy was evaluated prospectively in 259 pathologically verified thyroid nodules. Sonographic and pathologic correlation of calcifications was performed on 69 of 99 surgically removed nodules. Pathologic studies reve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

17
122
2
9

Year Published

1996
1996
2017
2017

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 193 publications
(151 citation statements)
references
References 8 publications
17
122
2
9
Order By: Relevance
“…Micro-calcification showed highest accuracy (76%), specifically (93%), and positive predictive value (70%) for malignancy as single Sonographic sign, but sensitivity (93%) was poor. 9 On color Doppler sonography, preference central hypervascularity was the most common finding in malignant nodules. Among benign nodules, preference perinodular hyper-vascularity was the most common finding.…”
Section: Malignant Nodulementioning
confidence: 99%
“…Micro-calcification showed highest accuracy (76%), specifically (93%), and positive predictive value (70%) for malignancy as single Sonographic sign, but sensitivity (93%) was poor. 9 On color Doppler sonography, preference central hypervascularity was the most common finding in malignant nodules. Among benign nodules, preference perinodular hyper-vascularity was the most common finding.…”
Section: Malignant Nodulementioning
confidence: 99%
“…demonstraram que a presença de microcalcificações no interior dos nódulos era a única característica ultra-sonográfica que poderia predizer malignidade (12). Este sinal teve acurácia de 76%, especificidade de 93% e valor preditivo positivo de 70%, mas com uma sensibilidade de apenas 36%.…”
Section: Calcificaçõesunclassified
“…Das várias combinações entre microcalcificações e um dos outros achados ultra-sonográficos, a combinação entre microcalcificações e nódulo de textura sólida mostrou a acurá-cia mais alta, de 77%, especificidade de 96% e valor preditivo positivo de 75%, porém a sua sensibilidade foi de apenas 30%. Esses resultados sugerem que, em casos de discrepância entre o diagnóstico ultra-sonográfico e o citológico, todos os outros dados clínicos devem ser considerados e uma nova biópsia para confirmação pode ser também considerada (12).…”
Section: Calcificaçõesunclassified
“…En ecografía, las microcalcificaciones en nódulos tiroideos y su relevancia para el diagnóstico ha sido ampliamente estudiada, existiendo una asociación fuerte entre su presencia y el riesgo de malignidad, en especial, en relación al cáncer papilar de tiroides (CPT) 1,2 . Desde un punto de vista anatomopatológico, se considera que representan la presencia de cuerpos de psammoma (CPs) (Figura 1) 3 .…”
Section: Introductionunclassified